Flow control may be classified into three types by transmission priority:
Condition 1: Precedence not determined by TOS.
Condition 2: TOS is rewritten; converted TOS determines precedence.
Condition 3: Precedence determined by input IP packet TOS.
Condition 4: Determines the EXP and priority level.
Condition 5: Determines the priority level by EXP.
Flow control is further classified using the following three conditions:
Condition 1: No reserve bandwidth management.
Condition 2: Detected flows that violate bandwidth reservation are discarded.
Condition 3: When a detected flow violates bandwidth reservation, its priority
is lowered.
Parameters
<IP List No.>
Description:
This parameter specifies the QoS IP frame condition list
number.
Default:
Only in display. The entire QoS IP frame condition list is
displayed.
Range of value:
1-1024
Flow Detection Condition Parameters
-protocol <No.>
Description:
This parameter specifies an upper-level protocol.
Table 1-83 Configurable Flow Control Parameters by Flow-control Type
Flow Control Parameter
Condition 1
Condition 2
Condition 3
Condition
4
Condition
5
1-1
1-2
1-3
2-1
2-2
2-3
3-1
3-2
3-3
4-1
5-1
-max_priority_class_X
*
*
*
-priority_class <No.>
-discard_class <No.>
*
*
*
*
*
-replace_tos <New_Tos Value>
††
††
††
-tos_map
††
††
††
-upc {no | <Bandwidth>}
*(1)
††(2) ††(2) *(1) ††(2) ††(2) *(1) ††(2) ††(2)
-upc_penalty drop
*
*
*
-upc_penalty
-modified_priority_class <No.>
-modified_discard_class <No.>
††
-upc_penalty
<Modified_New_Tos Value>
††
††
-replace_exp <Value>
††
††:
required,
†:
configurable,
*:
configurable; default,
blank:
not configurable,
numeral:
numeric setting
1:
no (or default value)
2: