Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2
3-8
GR2K-GA-0014
Ver. 07-02
3.1.2
history-control
Function
Object for creation, modification, deletion, and display of RMON (RFC1757) Ethernet
history-group control information. A maximum of 32 history-group control entries
can be registered per router.
Input Format
To create an RMON Ethernet history-group control entry:
[set] history-control <Index> -interface <Line Name>
[ -buckets_requested <Number> ] [ -interval <Seconds> ]
[ -owner <String> ]
To modify an RMON Ethernet history-group control entry:
[set] history-control <Index> [ -interface <Line Name> ]
[ -buckets_requested <Number> ] [ -interval <Seconds> ]
[ -owner <String> ]
To delete registered RMON Ethernet history-group control entries:
delete history-control <Index>
To show registered RMON Ethernet history-group control entries:
show history-control [ <Index> ]
Parameters
<Index>
Description:
Specifies the RMON Ethernet history-group control index
number. This parameter corresponds to
historyControlIndex
of
RFC1757.
Default:
Undefined (but cannot be omitted)
Range of value:
1-65535
-interface <Line Name>
Description:
Specifies the Ethernet line name subject to acquisition of the
RMON Ethernet history. This parameter corresponds to
historyControlDataSource
of RFC1757.
Default:
Undefined (but cannot be omitted)
Range of value:
Line name defined by the
line
subcommand
-buckets_requested <Number>
Description:
Sets the number of RMON Ethernet history-group control
entries. This parameter corresponds to
historyControlBucketsRequested
of RFC1757.
Default:
50
Range of value:
1-65535