Operation Management Information
GR2K-GA-0014
4-35
Ver. 07-02
4.7.3
Line Information (Ethernet/Gibabit Ethernet)
Input Format
[set]
default
[ -ethernet_type { auto_negotiation | 10m_ethernet | 10m_full_deplex |
100m_half_deplex | 100m_full_duplex } ]
[ -ethernet_tpid_9100 ]
[ { -gigabit_ethernet_flow_control | -gigabit_ethernet_flow_control_off}]
[ -gigabit_ethernet_mtu { 1500 | 1488 }]
[ -gigabit_ethernet_type { 1000m_full_duplex | auto_negotiation }]
[ -gigabit_ethernet_tpid_9100 ]
Parameters
The initial value items that can be set using line Information (Ethernet/Gibabit
Ethernet) and the initial values during initial installation are shown in Table 4-3. For
details of each parameter, refer to the configuration definition information in "line
Information (Ethernet/Gibabit Ethernet)."
Table 4-3
List of Initial Value Items that Can Be Set Using line Information (Ethernet /
Gigabit Ethernet) and Initial Values During Initial Installation
Information
Group Name
Information Name
Initial Value
line Information
(Ethernet /
Gigabit
Ethernet)
Segment standard of 10BASE-T and
100BASE-TX
Automatic recognition (auto negotiation)
Flow control function option in
1000BASE-LX, 1000BASE-SX, and
100BASE-LH
Enable
MTU length of 1000BASE-LX,
1000BASE-SX, and 100BASE-LH
1500 bytes
Segment standard of 1000BASE-LX,
1000BASE-SX, and 100BASE-LH
1000M full-duplex
10BASE-T,
100BASE-TX, 1000BASE-LX,
1000BASE-SX, TPID option in
100BASE-LH
0x8100