9-1-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 M
Ω
or more with DC 500 V Megohm Tester.
Dielectric strength:
AC 4000 V/1 minute, with no abnormalities
• • •
220 V --- 240 V
(and 110 V for U.K. products)
AC 2500 V/1 minute, with no abnormalities
• • •
110 V --- 127 V
(except U.K. products)
9-1-7. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows:
Voltage (V)
Current (A) (Max.)
110
115
220
230
5.9
5.7
3.0
2.8
240
2.7