2. ITEMS MONITORED BY THE RAS FEATURE
2-7
2.6.1 State transition of the RAID
Table 2-1 lists RAID statuses and their respective descriptions. Figure 2-2 shows the state
transitions.
Table 2-1 RAID Statuses and their Descriptions
RAID status
Description
Detailed
information
Normal
–
Redundant data is intact, and the RAID is operating normally.
Degraded
–
One drive failed, and a part of redundant data is corrupted.
Rebuild
The RAID is being rebuilt due to drive replacement or other reason.
Fail
–
Both drives failed, or drives are not connected.
Unknown –
Getting the RAID status failed, or the array configuration is not normal.
Figure 2-2 RAID Status Transitions
Degraded
Normal
Degraded
(Rebuild)
Fail
Media error occurs.
Degraded
One drive fails.
Drive
replacement
Error occurs
in the new drive.
RAID rebuild process is
complete.
(Read error occurs in
the copy source drive.)
Two drives fail.
RAID rebuild
process is complete.
Summary of Contents for HF-BT1000