4. CHECKING THE HARDWARE STATUS
4-17
(3) Timeout code
The timeout code is an error code that is displayed when a watchdog timer timeout
occurs. The timeout code is displayed only if “
Not reset
” is selected for
Action at
timeout
under
Watchdog timer setting
in the
RAS Setup
window. The timeout code is
displayed as flashing “88” regardless of the status display mode. For information about
the status display modes, see “4.4.3 Status display modes”.
Figure 4-11 Timeout Code
NOTE
The ON/OFF statuses of the status indication LEDs do not change before and
after the timeout code is displayed. For example, if an application status code is
displayed before the timeout code is displayed, the center status indication LED
remains on.
NOTICE
If you select “
Retriggered by application program
” under
Watchdog timer
setting
and “
Not reset
” for
Action at timeout
in the
RAS Setup
window, set the
status display digital LEDs to the application status display mode so that the
status code is not displayed there. Otherwise, the timeout code may be
overwritten by the status code and may not be able to be checked.