10. SOFTWARE RAID1
10-8
10.4 Recovering from failure
10.4.1 Detecting a failure
When failure is detected in the RAID1, the following actions are executed by this equipment.
Table 10-1 Action list of when the Software RAID detected failure
No. Action
Cause
1
The HDD status lamp (Red) turns on.
HDD failure
(Either one or both
HDDs)
2
The Digital LEDs for Status indication indicate an output message.
(See "9.6.1 POST messages" and refer to the HF-W2000 Model
48/45 RAS FEATURES MANUAL.)
3
he alarm lamp (Red) turns on.
HDD failure (Either
drive)
4
MCALL external contact (maintenance personnel call signal) is
closed.
(See "5.8.2 External control specifications".)
5
Data is recorded using the event log.
(See Section 9.4, "Event Log".)
6
The HDD status of the RAID1 system is displayed in the Hardware
status window.
(Refer to
“
4.1.3 Hardware status window
”
the HF-W2000 Model
48/45 RAS FEATURES MANUAL.)
The following part of this section describes how to recover from each type of failure and how
to handle the situation when a problem occurs during recovery work.
<Notice>
In this equipment, an operation is performed in the degeneracy of the other HDD
if it detects the failure of a HDD. When launching the first device after the
migration to degenerate behavior, in order to ensure the launch of deterrence from
the failed HDD, you may restart the equipment.
Summary of Contents for HF-W2000
Page 44: ...This Page Intentionally Left Blank ...
Page 72: ...This Page Intentionally Left Blank ...
Page 102: ...This Page Intentionally Left Blank ...
Page 133: ......
Page 134: ...This Page Intentionally Left Blank ...
Page 176: ...This Page Intentionally Left Blank ...
Page 204: ...This Page Intentionally Left Blank ...
Page 245: ...This Page Intentionally Left Blank ...
Page 279: ...This Page Intentionally Left Blank ...