Chapter 2 Specifications
Product
name
Model name
Specifications
I/O
assignment
symbol
Remarks
EH-AX44
12 bits analog input (4 to 20mA, 0 to 10 V) each 4 ch.
X8W
EH-AX8V
12 bits analog input 8 ch., Voltage (0 to +10 V)
X8W
EH-AX8H
12 bits analog input 8 ch., Voltage (
-
10 to +10 V)
X8W
EH-AX8I
12 bits analog input 8 ch., Current (4 to 20 mA)
X8W
EH-AX8IO
12 bits analog input 8 ch., Current (0 to 22 mA)
X8W
EH-AXH8M
14 bits analog input (0 to 22mA, 4 to 22mA,
-
10 to +10V, 0 to 10V) 8
ch.
X8W
EH-PT4
4 channels resistance bulb input, Signed 15 bits
Platinum (Pt 100
Ω
/ Pt 1000
Ω
)
X4W
Analog input
module
EH-TC8
Signed 15 bits, Thermocouple input (K, E, J, T, B, R, S, N) 8 points
X8W
Do not
mount on
the slave
base.
(Note 1)
EH-AY22
12 bits analog output (4 to 20mA, 0 to 10 V) each 2 ch.
Y8W
EH-AY2H
12 bits analog output 2 ch., Voltage (
-
10 to +10 V)
Y8W
EH-AY4V
12 bits analog output 4 ch., Voltage (0 to +10 V)
Y8W
EH-AY4H
12 bits analog output 4ch., Voltage (
-
10 to +10 V)
Y8W
EH-AY4I
12 bits analog output 4 ch., Current (4 to 20 mA)
Y8W
Analog output
module
EH-AYH8M
14 bits analog output (0 to 22mA, 4 to 22mA, 0 to 10V) 8 ch.
Y8W
Do not
mount on
the slave
base.
(Note 1)
EH-CU
2 channels high-speed counter input, Maximum frequency of 100 kHz,
1/ 2-phases switchover, 4-point opened collector output
X5Y3W
EH-CUE
1 channel high-speed counter input, Maximum frequency of 100 kHz,
1 /2-phases switchover, 2-point opened collector output
X5Y3W
EH-POS
1-axis pulse positioning module
X4Y4W
Positioning and
counter module
EH-POS4
4-axes pulse positioning module
X4Y4W
Do not
mount on
the slave
base.
(Note 1)
EH-ETH
Ethernet module IEEE802.3 standard, 10BASE-T, 8 units per CPU
COMM
(ETH)
EH-LNK
CPU link module (coaxial), 8 units per CPU
LINK
EH-OLNK
CPU link module (optical fiber), 8 units per CPU
LINK
EH-OLNKG
CPU link module (support optical fiber GI50/125
μ
m cable), 8 units per
CPU
LINK
EH-OLNKE
CPU link module (support optical fiver GI62.5/125
μ
m cable), 8 units
per CPU
LINK
EH-RMD
Device Net master module
CPU link assignment
…
256/256 words I/O, 8 units per CPU
Remote 2 assignment
…
64 words I/O total, 4 units per CPU can be
installed
LINK
/
REMOTE2
EH-RMP
PROFIBUS-DP master module,
256/256 words I/O, 8 units per CPU can be installed
LINK
EH-IOCD
Device Net slave module, 256 words input/256 words output
-
EH-IOCP
PROFIBUS-DP slave controller, 208 words I/O
-
EH-SIO
Serial communication module, RS-232C / RS-422 / RS-485
general-purpose,
Modbus protocol, Hi-Protocol, Simple data link
4W/4W
(SIO)
Communication
and network
module
EH-TRMME
Compact remote master module
REMOTE2/
4W/4W
Do not
mount on
the slave
base.
(Note 1)
Dummy
module
EH-DUM
Module for an opened slot
Empty16
(Note 2)
(Note 1) 32-point/64-point modules, analog I/O modules, high-performance modules, and communication modules, etc. cannot
operate normally on the slave base.
(Note 2) In the case of EHV, Please set “X16” or “Y16” for I/O assignment of dummy module. If you set “Empty” for I/O
assignment of dummy module, slot numbers of right side of dummy module become wrong.
2 – 6