Chapter 5 Instruction Specifications
5-82
Item number
Application instructions-12
Name
Block transfer (MOVE)
Ladder format
Condition code
Processing time (
µ
s)
Remark
R7F4
R7F3
R7F2
R7F1
R7F0
Average Maximum
MOV (d, s, n)
DER
ERR
SD
V
C
↕
z
z
z
z
Instruction format
Number of steps
Condition
Steps
As per the table
below.
MOV (d, s, n)
4
Bit
Word
Double word
Usable I/O
X
Y
R,
M
TD, SS,
CU, CT
WX WY
WR,
WM TC DX DY
DR,
DM
C
o
nstant
Other
d
Transfer destination head I/O
{
{
s
Transfer source head I/O
{
{
n
Number of bits (words)
to be transferred
{
{
{
{
{
The constant is set in
decimal.
Function
•
Transfers n bits (words) between s and s + n
−
1 to d + n
−
1.
•
The values between s and s + n
−
1 are retained. However, if the transfer source and transfer destination ranges overlap, the
transferred values will be used.
d+n-1
s+n-1
s
d
Before execution
After execution
n bits (words)
If n is a word:
The contents (0 to 255) of the lower 8 bits (b7 to b0) of n (WX, WY, WR, WM, TC) are set to the
number of bits (words) to be transferred.
If n is a constant:
0 to 255 (decimal) can be designated for the number of bits (words) to be transferred.
Notes
•
Use this instruction so that d + n
−
1 and s + n
−
1 do not exceed the I/O range (R7BF, M3FFF, WRFFF, and WM3FF). If
the I/O range is exceeded, DER is equal to '1' and the transfer is performed to the maximum range.
•
If n is equal to “0,” the block transfer is not performed and DER (R7F4) will be set to “0.”
MOV
(
d,
s,
n
)
Processing time (
µ
s) (Average)
n
Bit
Word
1
153
124
16
165
154
32
166
197
64
175
282
128
199
430
255
226
780
Summary of Contents for HIDIC MICRO-EH
Page 1: ...HITACHI PROGRAMMABLE CONTROLLER APPLICATION MANUAL NJI 350B X ...
Page 12: ...MEMO ...
Page 14: ...Chapter 1 Features 1 2 MEMO ...
Page 50: ...Chapter 4 Product lineup and wiring 4 18 MEMO ...
Page 196: ...Chapter 5 Instruction Specifications 5 146 ...
Page 263: ...Chapter 11 Communication Specifications 11 10 MEMO ...