Chapter 6 I/O Specifications
6-2
6.1
I/O Assignment
I/O assignment and I/O address are listed below.
Table 6.2 I/O assignment and I/O address
Type
I/O assignment
10-point
type
14-point
type
23-point
type
28-point
type
Slot 0 : X48
X0-5
X0-7
X0-12
X0-15
Slot 1 : Y32
Y100-103
Y100-105
Y100-109
Y100-111
Digital
Slot 2 : Empty
-
-
-
-
Slot 3 : X4W
-
-
WX30-31
-
Basic
Analog
Slot 4 : Y4W
-
-
WY40
-
-
X1000-1007 / 1015 (14 / 28 pts.)
Digital
Unit 1 / Slot 0 : B1/1
-
Y1016-1021 / 1027 (14 / 28 pts.)
-
WX101-104 (WX100 is for command function under development)
Exp.1
Analog
Unit 1 / Slot 0 : FUN0
-
WY106-107 (WY105 is for command function under development)
-
X2000-2007 / 2015 (14 / 28 pts.)
Digital
Unit 2 / Slot 0 : B1/1
-
Y2016-2021 / 2027 (14 / 28 pts.)
-
WX201-204 (WX200 is for command function under development)
Exp.2
Analog
Unit 2 / Slot 0 : FUN0
-
WY206-207 (WY205 is for command function under development)
-
X3000-3007 / 3015 (14 / 28 pts.)
Digital
Unit 3 / Slot 0 : B1/1
-
Y3016-3021 / 3027 (14 / 28 pts.)
-
WX301-304 (WX300 is for command function under development)
Exp.3
Analog
Unit 3 / Slot 0 : FUN0
-
WY306-307 (WY305 is for command function under development)
-
X4000-4007 / 4015 (14 / 28 pts.)
Digital
Unit 4 / Slot 0 : B1/1
-
Y4016-4021 / 4027 (14 / 28 pts.)
-
WX401-404 (WX400 is for command function under development)
Exp.4
Analog
Unit 4 / Slot 0 : FUN0
-
WY406-407 (WY405 is for command function under development)
Summary of Contents for HIDIC MICRO-EH
Page 1: ...HITACHI PROGRAMMABLE CONTROLLER APPLICATION MANUAL NJI 350B X ...
Page 12: ...MEMO ...
Page 14: ...Chapter 1 Features 1 2 MEMO ...
Page 50: ...Chapter 4 Product lineup and wiring 4 18 MEMO ...
Page 196: ...Chapter 5 Instruction Specifications 5 146 ...
Page 263: ...Chapter 11 Communication Specifications 11 10 MEMO ...