HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE SYSTEM
PAGE:6/30
Table 2
Item
Operating Envelope
(
see graph 1
)
Refrigerant
R410A
R452B
R454C
R454B
Discharge pressure
MPa{kgf/cm
2
G}
4.279 MAX
(condensing
temperature:
65℃)
4.039 MAX
(condensing
temperature
65℃)
3.124 MAX
(condensing
temperature:
70℃)
3.991 MAX
(condensing
temperature:
65℃)
Suction Pressure
MPa{kgf/cm
2
G}
0.272~1.652
0.254~1.562
0.172~1.084
0.251~1.543
(Evaporation Temperature
:-30℃~25℃)It can also be 0.101~0.172
MPa when in transition , but should not be used when it is less
than 0.101MPa
Compressor case bottom temp
99
℃
or below and 6 degrees higher than condensing temperature
Motor winding temp.
R a t e d v o l t a g e :
:
105
℃
M A X
Ra
t
e
d Voltage±10%:
120
℃
MAX
Accumulator temp
Higher than outlet pipe of evaporator
N o t e s : O v e r l o a d c o n d i t i o n s h o u l d n o t b e c o n t i n u o u s .
G
raph 1(a)
P1
P2
P3
P4
P5
Condensing temperature
65
℃
28
℃
5
℃
45
℃
65
℃
Evaporation Temperature
25
℃
25
℃
-30
℃
-30
℃
-5
℃