D C I N V E R T E R C O M P R E S S O R C R I T E R I A
PAGE:5/32
COMPRESSOR CRITERIA
1
Strictly observe the specification
The compressor should be used in specifications written in this
“
compressor specification
”
and
not be used in specifications outside it. Moreover, accessories should be specified parts used in
specified way, service must use specified parts too. The main circuit must link up
with fuse or
breaker.
2 Source voltage
Specified inverter is linked up with compressor terminals . Applied voltage of this inverter
should
be voltage specified in this
“
compressor specification
”
. Alternating voltage should
never be
applied on terminals (for example:commercial alternating voltage of
1
φ
100V,200V,3
φ
200V).This is
because that if applied alternating current the direct
current motor will demagnetize.
3 Operating voltage range
The compressor should be operated in the range of rated voltage 10% , under standard condition
and overload condition of rated frequency (applied voltage to inverter).
It must be satisfied with item 5, 6, 7 and the overload condition should not be continuous.
But the standard condition and overload condition mentioned here refer to condition that specified
in GB/T 7725. (The standard condition refers to the rating cooling condition and the overload
condition refers to the maximum operating condition.)
4 Operating temperatures and pressures
The operating temperatures and pressures of a compressor should be within the range shown in
the table 1.
Summary of Contents for HIGHLY WHP08750VCDNC9AU
Page 18: ...PAGE 16 32 ...
Page 19: ...PAGE 17 32 ...
Page 20: ...PAGE 18 32 ...
Page 21: ...PAGE 19 32 ...
Page 22: ...PAGE 20 32 ...
Page 23: ...PAGE 21 32 ...
Page 24: ...PAGE 22 32 ...
Page 25: ...PAGE 23 32 ...
Page 26: ...PAGE 24 32 ...
Page 27: ...PAGE 25 32 ...
Page 30: ...PAGE 28 32 ...
Page 34: ...PAGE 32 32 ...