S U B J E C T
M o d e l W H P 1 1 5 0 0 V S D P C 9 E Q S P E C I F I C A T I O N
PAGE:2/30
*.COP= Heating capacity
Motor input (W)
*.Rated Capacity and input are measured with HIGHLY inverter circuit by secondary Refrigerant
calorimeter Methods of JIS B8606 by Shanghai Highly Electrical Appliances Co., Ltd.
Allowable capacity should be more than 95% of the rated capacity and allowable input
should be less than 107% of rated motor input.
2.6 Refrigerant
R410A/R452B/R454C
/R454B
2.7 Displacement
30. 7
ml /re v
2.8 Al lowab le freque ncy range
900 ~ 7200 min
-1
2.9 Oil
α 6 8HES-H or equivale nt 1550
±
20m l
2.1 0 Allowa ble amount of refrig erant
c h a r g e
Below 4500g
2.11 Compressor cooling
Forced air
2.12 Hermetic Terminal
2.1 3 Space v olume of inner cas e
2628c m
3
2.14 Compressor weight
19.3kg incl. Oil
2.15 Motor Type
Insulation class
Direct current brushless
motor
E class
2.16
Compressor natural frequency
19.9Hz/21.7Hz/24.5Hz
Sollten vermieden (übersprungen) werden
3. THE PARAMETER OF MOTOR
I t e m
S p ec
E
xplanation
3.1
Rotor Pole
(
Pole
)
4
——
3.2
Rated Frequency Range
(
Hz
)
30-240
Electrical Frequency,Relating to
VDCmax of Inverter
3.3
Demagnetizing Current
(
A
)
54.01A
Peak Current
,
at 120
℃,
-5%
Demagnetizing Rate
Summary of Contents for Highly WHP11500VSD
Page 8: ...Arbeitsbereich siehe Bild 1 20 C A ...
Page 19: ...17 30 ...
Page 20: ...18 30 ...
Page 21: ... 19 30 ...
Page 22: ...20 30 ...
Page 23: ...21 30 ...
Page 24: ...22 30 ...
Page 25: ...23 30 ...
Page 26: ...24 30 ...
Page 27: ...25 30 ...
Page 28: ...26 30 ...
Page 30: ...28 30 ...
Page 31: ...CHART 3 Instructions forInverter rotary compressor revolutions change 29 30 ...