S U B J E C T
M o d e l W H P 1 3 3 0 0 P S D P C 8 F Q S P E C I F I C A T I O N
PAGE:2/31
*.COP= Heating capacity (W)
Motor input (W)
*.Rated Capacity and input are measured with HITACHI inverter circuit by secondary Refrigerant
calorimeter Methods of JIS B8606 by SHANGHAI HIGHLY Electrical Appliances Co., Ltd.
2.6 Refrigerant
R29 0
2.7 Displacement
54.8ml /rev(Double-cylinder
2.8 Al lowab le freque ncy range
900 ~ 6600 min
-1
2 . 9 O i l
HAF68 11 50
±
20m l
2.1 0 Allowa ble amount of refrig erant
c h a r g e
Below 1500g
2.11 Hermetic Terminal
Conventinal Type
2.1 2 Space v olume of inner cas e
1500c m
3
2.13 Compressor weight
18.9kg incl. Oil
2.14 Motor Type
Insulation class
Direct current brushless motor E class
2.15
Compressor natural frequencies
19.9Hz/21.7Hz/24.5Hz±3Hz(should be avoided or
pass within ten seconds
are compressor natural
frequencies, and they can be changed when connecting
with pipe lines. So, it is necessary to take the
piping stress of the system into account. The
recommended piping stress value
can be seen as follow,
When the system Start/stop:below 34.3N/mm
2
When the system operating:below 17.7N/mm
2