11
q
Press the
START
button.
w
START
light glows and the compressor starts.
e
Gradually closing the discharge side valve,
and keep running-in of the machine at the dis-
charge pressure of 0.49-0.59 MPa for an hour.
r
Be sure that the oil level is kept between two
red lines during operation.
t
Press the
SELECT
button on the instrument
panel to display the discharge air tempera-
ture. Make sure that it is stable between 65
°
C
and 100
°
C.
y
Make sure that, 5 to 10 minutes after starting,
the refrigerant pressure gauge reads 0.41 to
0.73 MPa.
u
Make sure that, about 20 minutes after start-
ing, the automatic condensate trap starts drain-
ing the condensate.
3. HOW TO OPERATE [Initial Start-Up]
3.3.3 Operation
3.3.4 Stop
q
Press the
STOP
button.
The compressor stops.
w
Be sure that the pressure at
DISCHARGE AIR
PRESSURE GAUGE
indicates 0 (It returns to
0 for about 1 or 2 minutes after stop.)
e
Fully close the valve on discharge side.
r
Disconnect the power.
⑤
①②
⑦
⑥
③
④
② ①
④
③
Power
Supply