16
q
Press the
START
button.
Make sure that the air compressor starts.
・
For the air dryer prestarting (
☞
p. 14) disabled:
Make sure that the built-in air dryer starts
simultaneously.
・
For the air dryer prestarting enabled:
Make sure that the built-in air dryer prestarts,
the
AUTO START
light flashes for 3 minutes,
and then the air compressor starts.
w
Make sure that the oil level during operation
is kept within the range between the red lines.
e
If it is below the lower line, follow the proce-
dure on page 18 and replenish the genuine
synthetic oil (
NEW
A
OIL 2000
).
r
Digital monitor displays run hour in 10 hours
as a unit.
Press the
SELECT
button on the instrument
panel and check if the discharge temperature
is within the range between 65
°
C and 100
°
C.
(After temperature stabled)
t
Make sure that, 5 to 10 minutes after starting,
the refrigerant pressure gauge reads 0.41 to
0.73 MPa.
y
Make sure that, about 20 minutes after start-
ing, the automatic condensate trap starts drain-
ing the condensate.
3. HOW TO OPERATE [Daily Operation]
3.5.3 Operation
3.5.4 Stop
q
Press the
STOP
button.
The compressor stops.
w
Be sure that the pressure at
DISCHARGE AIR
PRESSURE GAUGE
indicates 0 (It returns to
0 for about 1 or 2 minutes after stop.)
e
Fully close the valve on discharge side.
r
Disconnect the power.
④
①
⑥
⑤
②
② ①
④
③
Power
Supply