69
12. STANDARD SPECIFICATION
Operating gas
Suction pressure
Suction temperature
Discharge pressure
Discharge air capacity
Discharge temperature
Main motor output
Main motor type
Fan motor output
Fan motor type
Starter type
Lubricating oil
Lubricating oil filling amount
Dryer outlet dew point (under pressure)
Dryer refrigerator nominal output
Condenser fan motor output
Coolant used
Total weight
Size (Width
×
Depth
×
Height)
■
Compressor Specification
Air
Ambient pressure
0 to 40 [5 to 40]
Atomospheric tempe 15
Totally enclosed, external-fan cooled
Totally enclosed
Star-Delta Starting
NEW
A
OIL 2000 (genuine synthetic oil)
U-type (suction throttle type) +
I
-type (vacuum type)
U-type (suction throttle type) +
I
-type (vacuum type) + P-type (auto start/stop)
10
1.1
℃
MPa
m
3
/min
℃
kW
kW
liter
S-type
M-type
℃
kW
W
kg
mm
0.83
0.92
0.69
0.92
0.69
0.83
3.1
2.9
3.8
5.0
6.3
5.3
760 [830]
1,400
×
970
×
1,400
540 [590]
1,200
×
890
×
1,260
25
×
2
25
×
1
13
8
37
22
Item
Unit
OSP-22S5A(R)
I
/ S6A(R)
I
OSP-22M5A(R)
I
/ M6A(R)
I
OSP-37S5A(R)
I
/ S6A(R)
I
OSP-37M5A(R)
I
/ M6A(R)
I
NOTE (1) means standard specifications.
(2) Discharge air capacity is a converted value according to the suction condition of the compressor.
(3) Dew point shown is the value measured in an environment with ambient temperature 30
°
C., discharge pressure 0.69 MPa.
(4) Do not select U-type control for 0.92MPa discharge pressure model.
(5) The values in the brackets are for the models with a built-in air dryer.
R407C (600 g)
R407C (360 g)
Capacity control type
1.5
0.75