3.3.3 Operation
①
Press the
START
button.
②
START
light glows and the compressor starts.
③
Gradually closing the discharge side valve, and keep
running-in of the machine at the oil separator tank
internal pressure gauge of 0.5-0.6 MPa for an hour.
④
Be sure that the oil level is kept between two red
lines during operation.
See the section 4.3.1 of this manual.
⑤
Press the
SELECT
button on the instrument panel
to display the discharge air temperature. Make sure
that it is stable between 65
℃
and 100
℃
.
3.3.4 Stop
④
③
②
Power
Supply
RUNNING CONTROL
RUNNING MODE
ALARM
警 报
运行状况
故 障
LOAD
SHUTDOWN
REMOTE
负 载
远 程
电 源
POWER
自动启动
AUTO START
停 机
STOP
开 机
START
1
2
存 储
远 程
REMOTE
显示转换
/
扩展模式
STR
功 能
FUNC
重新设定
RESET
SELECT/WIDE
运行管理
①
⑤
①
Press the
STOP
button.
The compressor stops.
②
Open the front door and make sure the oil separator
tank internal pressure gauge reads 0 MPa.
(It returns to 0 for about 1 or 2 minutes after stop.)
③
Fully close the valve on discharge side.
④
Disconnect the power.
⑤
The instrument panel
POWER
light goes off after
about 10 minutes.
●
If the compressor starts with the ambient temperature
below the lower limit defined in the specification, the
machine may start in about 20 seconds after 1 to 2 sec-
ond jog operation.
This sequence is controlled by the retry function and,
therefore, is not a trouble. If this is your case, “E0.44”
may be displayed on the digital monitor and the
STANDBY light blinks.
Discharge air pressure displayed on the instrument panel
is unit exit side pressure (minimum pressure / check valve
downflow side pressure). If there is pressure remaining in
the air tank, the gauge does not read 0 MPa.
The oil separator tank internal pressure gauge (minimum
pressure / check valve upflow side pressure) drops to 0
MPa by stopping the compressor.
③
④
RUNNING CONTROL
RUNNING MODE
ALARM
警 报
运行状况
故 障
LOAD
SHUTDOWN
REMOTE
负 载
远 程
电 源
POWER
自动启动
AUTO START
停 机
STOP
开 机
START
1
2
存 储
远 程
REMOTE
显示转换
/
扩展模式
STR
功 能
FUNC
重新设定
RESET
SELECT/WIDE
运行管理
①
②
⑤
IMPORTANT
IMPORTANT
●
If restarting immediately after stopping operation, “E0.57”
may be displayed on the digital monitor due to fan motor
overload protection and the compressor may stop.
If restarting after stopping, be sure to wait at least 1 min-
ute before restarting.
12
3. HOW TO OPERATE [Initial Start-Up]