7K320 (SATA) OEM Specification
Page 121 of 176
14.23
Read Sector(s) Ext (24h)
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3
2
1
0 Register
7
6 5 4 3 2
1
0
Data
Low
- - - - -
-
-
- Data
Low
-
- - - - -
-
-
Data
High
- - - - -
-
-
- Data
High
-
- - - - -
-
-
Current
- - - - -
-
-
- Error
...See
Below...
Feature
Previous - - - - -
-
-
-
Current
V V V V V V V V
HOB=0
-
- - - - -
-
-
Sector Count
Previous V V V V V V V V
Sector Count
HOB=1
-
- - - - -
-
-
Current
V V V V V V V V
HOB=0 V V V V V V V V
LBA Low
Previous V V V V V V V V
LBA Low
HOB=1 V V V V V V V V
Current
V V V V V V V V
HOB=0 V V V V V V V V
LBA Mid
Previous V V V V V V V V
LBA Mid
HOB=1 V V V V V V V V
Current
V V V V V V V V
HOB=0 V V V V V V V V
LBA High
Previous V V V V V V V V
LBA High
HOB=1 V V V V V V V V
Device
- 1 - - -
-
-
- Device
-
- - - - -
-
-
Command
0 0 1 0 0
1
0
0 Status
...See
Below...
Error Register
Status Register
7 6 5 4 3 2 1 0
7 6 5
4 3 2 1 0
CRC
UNC 0 IDN 0 ABT T0N AMN BSY
RDY DF
DSC
DRQ
COR IDX
ERR
0 V 0 V 0 V 0 0 0 V 0
V - 0 0 V
Table 90 Read Sector(s) Ext Command (24h)
The Read Sector(s) Ext command reads from 1 to 65,536 sectors of data from disk media, then
transfers the data from the device to the host.
The sectors are transferred through the Data Register 16 bits at a time.
If an uncorrectable error occurs, the read will be terminated at the failing sector.
Output Parameters To The Device
Sector Count Current
The number of sectors to be transferred low order, bits (7:0).
Sector Count Previous
The number of sectors to be transferred high order, bits (15:8). If 0000h in the Sector
Count register is specified, then 65,536 sectors will be transferred.
LBA Low Current
LBA (7:0)
LBA Low Previous
LBA (31:24)
LBA Mid Current
LBA (15:8)
LBA Mid Previous
LBA (39:32)
LBA High Current
LBA (23:16)
LBA High Previous
LBA (47:40)
Input Parameters From The Device
LBA Low (HOB=0)
LBA (7:0) of the address of the first unrecoverable error.
LBA Low (HOB=1)
LBA (31:24)of the address of the first unrecoverable error.
LBA Mid (HOB=0)
LBA (15:8)of the address of the first unrecoverable error.
LBA Mid (HOB=1)
LBA (39:32)of the address of the first unrecoverable error.
LBA High (HOB=0)
LBA (23:16)of the address of the first unrecoverable error.
LBA High (HOB=1)
LBA (47:40)of the address of the first unrecoverable error.