Table 9-1 System log messages
Message ID
Condition
Cause
Recommended action
HORCM_001
The HORCM log file
cannot be opened.
The file cannot be created
in the HORCM directory.
Create space on the disk on
which the root directory resides.
HORCM_002
The HORCM trace file
cannot be opened.
The file cannot be created
in the HORCM directory.
Create space on the disk on
which the root directory resides.
HORCM_003
The HORCM daemon
process cannot create
a child process due to
an error.
HORCM daemon attempted
to create more processes
than the maximum
allowable number.
Terminate unnecessary programs
or daemon processes running
simultaneously.
HORCM_004
HORCM assertion
failed, resulting in a
fatal internal error in
the HORCM.
An internal error that could
not be identified by the
HORCM occurred.
Restart the system, and contact
Hitachi Data Systems customer
support.
HORCM_005
The CCI software
failed to create the end
point for remote
communication.
HORCM failed to create a
socket, or an error exists in
the format or a parameter
in the HORCM
configuration definition file
($HORCM_CONF).
Refer to the HORCM startup log
to identify the cause of the error.
HORCM_006
HORCM memory
allocation failed.
HORCM memory could not
be secured.
Increase the system virtual
memory, or close any
unnecessary programs.
HORCM_007
An error exists in the
parameter value in the
HORCM setup file.
An error exists in the
parameter value setting in
the HORCM setup file.
Refer to the startup log and reset
the parameters.
HORCM_008
HORCM configuration
definition file
parameters reading
fails.
An error exists in the
format or parameters of
the HORCM configuration
definition file
($HORCM_CONF).
Refer to the HORCM startup log
to identify the cause of the error.
HORCM_009
TrueCopy/
ShadowImage
connection to the CCI
software failed.
System devices are
improperly connected, or
an error exists in the
device parameter in the
HORCM configuration
definition file.
Refer to the HORCM startup log
to identify the cause of the error.
HORCM_101
TrueCopy/
ShadowImage and the
CCI software
communication fails.
A system I/O error
occurred or an error exists
in the device parameter in
the HORCM configuration
definition file
($HORCM_CONF).
Refer to the HORCM startup log
to identify the cause of the error.
HORCM_102
The volume is
suspended.
The pair status was
suspended due to code
XXXX.
Contact Hitachi Data Systems
customer support.
HORCM_103
Detected a validation
check error on this
volume (xxxx
unit#x,ldev#x):
A validation error occurs on
the database volume, or
validation parameters for
this volume are illegal.
Please confirm the following
items, and use
raidvchkdsp -v
Troubleshooting
9-7
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...