Table 9-19 SSB codes returned by raidcom add ldev
raidcom add ldev
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
2E00
0000
The LDEV number is out of settable range.
CMDRJE
Get Command
Status
Executing/
Async
2E00
0002
The specified capacity is not in the effective range.
CMDRJE
Executing
2E00
0003
SSID is not in the effective range.
CMDRJE
Executing
2E00
000D
The value of the specified emulation type is invalid.
CMDRJE
Get Command
Status
Executing/
Async
2E00
000E
The specified emulation type is not supported in
this command.
Get Command
Status
Async
2E00
0010
The operation cannot be performed because the
specified LDEV number is already used.
Get Command
Status
Async
2E00
0013
The operation cannot be performed because there
are not enough cache management devices.
Get Command
Status
Async
2E00
0014
Cannot create because the specified capacity is
invalid.
CMDRJE
Executing
2E00
0019
The capacity in the case of specifying a emulation
type of the mainframe series must be dividable by
the cylinder.
CMDRJE
Executing
2E00
001A
The capacity when 3390-V emulation type is
specified must be divisible by page unit.
CMDRJE
Executing
2E00
001C
When you specify emulation type for open system,
you cannot specify the size by the cylinder.
CMDRJE
Get Command
Status
Executing/
Async
2E00
0025
The following external volume cannot be created
because the capacity which is specified with LBA is
not same as the size of the external volume group.
•
An external volume for the online data
migration.
•
An external volume having the Data Direct
Mapping attribute.
CMDRJE
Executing
2E00
0026
The capacity must be specified because LDEVs are
in the parity group (or the external volume group).
CMDRJE
Executing
2E00
0027
The capacity must be specified.
Get Command
Status
Async
2E00
002D
The emulation type of the mainframe cannot be
specified because the virtual volume is set for the
specified LDEV.
CMDRJE
Executing
2E00
002F
The specified value of the Full Allocation is invalid.
Get Command
Status
Async
2E00
0030
Full Allocation cannot be specified to the specified
LDEV because the emulation type is not supported.
Troubleshooting
9-39
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...