raidcom add ldev
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
ERANGE Result too
large
Executing
-
-
The value of the capacity is invalid.
Table 9-20 SSB codes returned by raidcom delete journal
raidcom delete journal
Error message
Executing/
Async
Error code
Description
SSB1
SSB2
CMDRJE
Executing
2E00
0000
The number of specified LDEV is invalid.
Get Command
Status
Async
2E00
0023
The specified volume capacity is too small.
CMDRJE
Executing
2E00
5000
The specified journal ID is exceeds the range.
Get Command
Status
Async
2E10
0011
The specified volume is not installed or cannot be
used.
Get Command
Status
Async
2E10
0053
The specified volume is used in maintenance
operation.
Get Command
Status
Async
2E10
5000
The specified operation failed because the journal
or mirror is not in the operable status.
Get Command
Status
Async
2E10
5010
The journal volume cannot be deleted with the
specified journal status.
Get Command
Status
Async
2E11
800B
The operation cannot be performed because it is in
the state of start-up.
Get Command
Status
Async
2E11
800E
The operation cannot be performed because the
internal processing is in progress. Wait for a while,
then retry the operation.
CMDRJE
Executing
2E11
9400
The command cannot be accepted. After a while,
execute the same command.
CMDRJE
Executing
2E13
5002
The specified LDEV is not in the journal.
CMDRJE
Executing
2E20
5000
The specified journal ID is not registered.
Get Command
Status
Async
2E21
5000
The operation failed because the specified journal
is not registered.
Get Command
Status
Async
2E21
8104
The journal volume cannot be added, or the
journal cannot be added to the extended
consistency group due to insufficient capacity of
the shared memory.
CMDRJE
Executing
2E21
8105
The shared memory for Universal Replicator is not
installed.
CMDRJE
Executing
2E23
0008
The number of specified LDEVs is invalid.
Troubleshooting
9-45
Command Control Interface User and Reference Guide
Summary of Contents for HUS VM
Page 10: ...x Command Control Interface User and Reference Guide ...
Page 18: ...xviii Preface Command Control Interface User and Reference Guide ...
Page 78: ...2 50 CCI software environment Command Control Interface User and Reference Guide ...
Page 154: ...4 8 Starting up CCI Command Control Interface User and Reference Guide ...
Page 191: ...Provisioning operations with CCI 5 37 Command Control Interface User and Reference Guide ...
Page 280: ...6 56 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 286: ...6 62 Data replication operations with CCI Command Control Interface User and Reference Guide ...
Page 302: ...7 16 Data protection operations with CCI Command Control Interface User and Reference Guide ...
Page 324: ...8 22 Examples of using CCI commands Command Control Interface User and Reference Guide ...
Page 524: ...9 200 Troubleshooting Command Control Interface User and Reference Guide ...
Page 529: ...Command Control Interface User and Reference Guide ...