4-8
6 Pass Attaching pin through hole A and hole B for centering holes.
Mount Pressure reducing valve joint PRV on Ink circulation unit by Fastening screw
M4x12 (2 pieces). And then remove Attaching pin.
"Caution" : - Make sure that no O-ring drops out.
- Make sure to use Fastening screw M4x12.
- Be careful of the mounting direction of Pressure reducing valve joint PRV.
7 Mount Pressure reducing valve on Pressure reducing valve joint PRV by Fastening screw
M4x16 (2 pieces).
"Caution" : Be careful of the mounting direction of Pressure reducing valve. (Turn
‘Al’
mark to the lower side.)
8 Perform
“Ink Replenishment” and adjust the pressure.
Make sure that there is no ink leak.
Fastening screw M4X12
Attaching pin
Pressure reducing valve joint PRV
Ink circulation unit
Hole A
Hole B
Joint nut
Fastening screw M4X16
Pressure reducing valve
Pressure reducing valve joint PRV
‘Al’ mark