2-24
2.7 Ink concentration control
●
Select whether or not the ink concentration is controlled based on results of the viscosity
measurement.
●
Perform these settings
at “Stop” state.
Setting items of circulation environment setup screen
Item
Selection
Contents
Ink concentration control
Disable
The ink concentration is controlled by the
dot count control without measurement of
the ink viscosity.
(Dot count control: Amount of ink which is
used for printing and vaporized makeup
are automatically refilled.)
Enable
The ink concentration is controlled based
on results of the viscosity measurement.
1 Press Circulation environment setup Start/Continue on the second page of
the circulation control menu of maintenance.
The circulation environment setting screen is then displayed.
*Caution:
1. Under ordinary circumstances, the default setting of “ink concentration control”
is “Enable.”
2.
”Enable” can not be selected for some inks.
In this case, ink concentration is not controlled by the viscometer,
but is controlled by dot count.
The default setting is “Enable.”
Back
Ink type 002 (JP-K69)
Ink concentration control
Enable
Disable
Circulation env. setup
HOME
[Stop ]
2015.07.07 12:45
Com=0
Summary of Contents for IJ RX2
Page 1: ...Service Manual HITACHI Printer Model RX2 Revision Feb 2014 Version A ...
Page 13: ...1 8 2 External views Rear side 1 2 2 Main body internal ...
Page 14: ...1 9 1 2 3 Print head ...
Page 101: ...3 26 Circuit diagram of EZJ127A ...
Page 102: ...3 27 Circuit diagram of EZJ127B ...
Page 116: ...3 41 Circuit diagram of EZJ129 ...
Page 164: ...4 40 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 247: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram 7 1 ...
Page 249: ...7 3 7 2 2 Electrical Connection Diagram RX2 B Basic model 7 3 ...