2-51
2.20
Logging data
- Log the operating conditions to investigate the fault and warning condition.
- Log files are copied to the below holder when backup function is performed in the Service
personnel maintenance mode.
List of Log files
No.
File name
Contents
Logging timing
1
ALARM.TXT
Fault and warning log
When Fault or Warning happens.
2
AUTOSPLY.TXT
Ink
and
makeup
replenishment data
When
ink
and
makeup
are
replenished automatically.
(Each 30 min.)
3
INKVISCO.TXT
Viscosity control
When
ink
and
makeup
are
replenished automatically.
(Each 30 min.)
4
SEQUENCE.TXT
Circulation system control
When circulation system control
sequence is done.
- Up to 480 logging data can be recorded. If the number of logging data exceeds 480, the oldest
data is erased.
1
Contents of each log file
The following examples show the image of the logging data (text file) is pasted to Microsoft Excel
format.
(1) Fault and warning log (ALARM.TXT)
[Example]
- Code: Log management code of each Fault and Warning.
(Refer to the 2.13 Fault / Warning log management code)
- Info1 to 4: Internal management code to specify the cause of alarm
№
Date
Time
Code
Message
Info1
Info2
Info3
Info4
1
2011/7/7
7:05:29
22 Internal Communication Error S
0x0004
0x0000
0
0
2
2011/7/7
7:06:56
176 Viscometer not Calibrated
0x0000
0x0000
0
0
3
2011/7/7
8:06:56
88 Battery Low
0x0000
0x0000
0
0
4
2011/7/7
9:07:45
17 Heating Unit Sensor Fault
0x0002
0x0000
32
12
5
2011/7/7
10:12:04
1 Ink Low Fault
0x0000
0x0000
0
0
6
2011/7/7
11:37:20
2 Main Ink Tank Too Full
0x0000
0x0000
0
0
7
2011/7/7
12:07:22
50 Cover Open
0x0000
0x0000
0
0
8
2011/7/7
12:14:45
209 Storage Media Error
0x0000
0x0000
0
0
Summary of Contents for IJ RX2
Page 1: ...Service Manual HITACHI Printer Model RX2 Revision Feb 2014 Version A ...
Page 13: ...1 8 2 External views Rear side 1 2 2 Main body internal ...
Page 14: ...1 9 1 2 3 Print head ...
Page 101: ...3 26 Circuit diagram of EZJ127A ...
Page 102: ...3 27 Circuit diagram of EZJ127B ...
Page 116: ...3 41 Circuit diagram of EZJ129 ...
Page 164: ...4 40 5 Reset the time of the R air filter to 0 on the Parts usage time management screen ...
Page 247: ...7 Attached Drawing 7 1 Circulation System Diagram Circulation System Diagram 7 1 ...
Page 249: ...7 3 7 2 2 Electrical Connection Diagram RX2 B Basic model 7 3 ...