--- 14 ---
9-5. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as specified below at a frequency of
60 Hz.
Voltage (V)
4.0
Current (A)
120
Note: For the Models M 12VC and KM 12VC, check the no-load current value by setting the dial to "6".