![background image](http://html.mh-extra.com/html/hitachi/l100dn-devicenet-series-addendum/l100dn-devicenet-series-addendum_read-this-first-manual_142290083.webp)
L100DN Inverter
83
A_94 Select method to switch to Acc2/
Dec2 profile
1
194
1
0 2CH input from
terminal
1 transition
frequency
—
G/S
A_95 Acc1 to Acc2 frequency transi-
tion point
1
195
2
0.0 – 360.0Hz
100
G/S
A_96 Dec1 to Dec2 frequency transi-
tion point
1
196
2
0.0 – 360.0Hz
100
G/S
A_97 Acceleration curve selection
1
197
1
0 linear
1 S-curve
—
G/S
A_98 Deceleration curve selection
1
198
1
0 linear
1 S-curve
—
G/S
“A” Group Parameters
DeviceNet Class ID = 101
Func.
Code
Name
Inst Attr Size
Range
Scaling
Get/
Set
Supported Services, DeviceNet Class ID = 101
Service Name
Code
Description
Get_Attribute_Single
0Eh
Set_Attribute_Single
10h