--- 33 ---
Check that Nail Feeder (B)
[80]
slides in the Magazine
[76]
smoothly.
Check that the Plunger
[69]
moves smoothly.
Check that Adjuster
[53]
turns smoothly by hand.
Check that there is no air leakage from each part.
Set Change Knob (C)
[45]
to "contact actuation" (see 5-2). While driving nails with an air pressure of
5 kgf/cm
2
(71 psi), check that there is no misfiring and bending of nails.
Note: Before conducting the driving test, turn the Adjuster
[53]
to the deepest position.
Set Change Knob (C)
[45]
to "single actuation (single sequential actuation)" (see 5-2). Check that the Model
NR 90AE operates by pressing Pushing Lever (A)
[34]
against a test piece first then pulling Trigger (C)
[49]
.
Check that the Piston
[13]
is still showing from the Nose
[28]
tip (outlet of nails) after Pushing Lever (A)
[34]
is
released from the test piece with Trigger (C)
[49]
pulled.
Recheck the tightening torque of each screw.
Check that Pushing Lever (A)
[34]
slides smoothly.
Check that the machine will not operate only by pulling Trigger (C)
[49]
. Also check that the machine will not
operate only by depressing Pushing Lever (A)
[34]
.
11. INSPECTION AND CONFIRMATION AFTER REASSEMBLY