After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of Hitachi pneumatic tool
lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor tank to
drain any moisture.
ADJUSTING THE NAILING DEPTH
To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(requlator is installed and working properly), and
2) the Nailer is always held
fi
rmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1
DISCONNECT AIR HOSE FROM NAILER.
Adjuster
Disconnect
air hose
15
2
If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half
-
turn increments.
2
Too Deep
Flush
Turn Adjuster
If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
Flush
2
Too Shallow
3
Stop turning the adjuster when a suitable position is
reached for a nailing test.
4
Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5
DISCONNECT AIR HOSE FROM NAILER.
6
Choose a suitable position for the adjuster.