--- 12 ---
8-2. Principle of Operation
(1) Before nailing
Fuel is not charged into the nailer in the initial
state. The combustion chamber is released
to the atmosphere (Fig. 4).
(2) When nailing
1) Push up the Pushing Lever
[64]
.
Then the nailer starts operation in the
following order (Fig. 5).
The Switch Plate
[34]
on the Chamber
[24]
pushes the Switch Arm
[82]
to turn on
the fan switch. The Fan
[20]
in the
combustion chamber rotates.
The Chamber Head
[22]
is sealed by the
O-ring
[15]
and the Chamber
[24]
surface
is sealed by the O-ring
[36]
simultaneously. Thus the combustion
chamber is cut off from the atmosphere.
The convex portion of the Chamber
[24]
pushes up the Tension Plate
[113]
on
Switch Lever (B)
[114]
to rotate Switch
Lever (B)
[114]
.
The protrusion of the Chamber Head
[22]
pushes up the tip of the Cell Lever
[105]
to rotate it. Thus the Cell Lever
[105]
pushes the back of the fuel cell to
spray fuel into the combustion chamber.
Fig. 5
Fig. 4
Fuel cell
Chamber
[24]
Cylinder Ass'y
[42]
Pushing
Lever
[64]
Fan
[20]
Combustion
chamber
Trigger
[98]
Chamber
[24]
Cell Lever
[105]
O-ring
[15]
Protrusion of
Chamber Head
[22]
Fan switch
Switch Lever (B)
[114]
Trigger
[98]
Switch Arm
[82]
Pushing Lever
[64]
Convex of Chamber
[24]
Switch Plate
[34]
Combustion
chamber
O-ring
[36]
Chamber
[24]
Tension Plate
[113]
Fan
[20]
Chamber Head
[22]