16
English
ADJUSTING THE NAILING DEPTH
WARNING
●
When adjusting the Adjuster, be sure to
remove your
fi
nger from the trigger and
disconnect the air hose from the nailer.
To assure that each nail penetrates to the same depth, be
sure that:
1) the air pressure to the Nailer remains constant
(regulator is installed and working properly), and
2) the Nailer is always held
fi
rmly against the workpiece.
If nails are driven too deep or shallow into the workpiece,
adjust the nailing in the following order.
1
DISCONNECT AIR HOSE FROM NAILER.
Adjuster
15
Disconnect
air hose
2
If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half
-
turn increments.
Too deep
Turn adjuster Flush
2
If nails are driven too shallow, turn the adjuster to the
deep side.
Too shallow
Turn adjuster Flush
2
3
Stop turning the adjuster when a suitable position is
reached for a nailing test.
4
Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a nailing test.
5
DISCONNECT AIR HOSE FROM NAILER.
6
Choose a suitable position for the adjuster.
USING THE BLOW NOZZLE
WARNING
●
Be sure to release your
fi
nger from the trigger
before using the blow nozzle.
●
Do not point the air outlet of blow nozzle at a
person.
●
Do not use the blow nozzle with the push
lever left
fi
t.
This Nailer has a blow nozzle that blows out wood
shavings which occur during work.
Press the knob with your thumb to use the blow nozzle, as
shown in the
fi
gure.
Blow nozzle knob
air outlet of
blow nozzle
NOTE
●
When the blow nozzle is used for a long time, the
nailing force may degrade temporarily. In this case,
allows the air supply pressure to stabilize before
starting work.
●
Oil in the body or drained water from the compressor
can sometimes spout out of the air outlet of blow
nozzle. It is recommended that you once conduct a
test before use and see if such phenomenon happens
at an environment where spouted oil will cause any
inconvenience.
CHANGING THE EXHAUST DIRECTION
WARNING
●
When changing the exhaust direction, be
sure to remove your
fi
nger from the trigger
and disconnect the air hose from the nailer.
The direction of the exhaust vent can be changed by
turning the top cover.
Exhaust vent
Top cover
000Book̲NT65M2(S)̲US.indb 16
000Book̲NT65M2(S)̲US.indb 16
2015/06/22 17:03:37
2015/06/22 17:03:37