--- 20 ---
<Driver blade is not returned
completely.>
See item "1) Output
section: piston, driver
blade, etc.".
Air pressure is too high.
Problem
Possible cause
( : Most-common cause)
Inspection method
Remedy
<Body: Nail feeding is
incomplete.>
Feeder is worn and the
sliding section is abnormal.
Nail guide face of the nose
or the sliding section of the
feeder is abnormal
(deformed, burrs or
damaged).
Feed spring or feeder spring
is abnormal (damaged,
fatigued or removed).
4) Nails jam.
(continued)
Open the nail guide and
check the position of the
feeder claw.
Replace the abnormal part.
<Body: Nail guide section>
Nail guide section is
abnormal.
See item "1) Nail guide
section".
Perform idle or actual
driving to check if the driver
blade is returned
completely.
Nails may be jammed if
driven at a high pressure
and high speed. Check
pressure and driving speed.
See item "1) Nail guide
section".
See item "1) Output section:
piston, driver blade, etc.".
Adjust the air pressure to
5 --- 8.5 kgf/cm
2
(4.9 --- 8.3
bar, 70 --- 120 psi).
Summary of Contents for NV 65AF3