-11-
Problem
Possible cause
( *: Most-common cause)
Inspection method
Corrective action
• Air leaks from the gap
between the body and the
nose.
• Tighten screws and check
the O-rings.
• O-rings are worn or
deformed.
• Replace the O-rings.
• O-rings need lubrication.
• Apply grease or lubricant.
<Nail guide section>
• Nail guide face is
abnormal (deformed,
burrs or damaged).
• Check that the nail guide
is not abnormal (worn,
deformed or damaged).
• Correct or replace the
parts.
• Dust adheres inside the
nail guide groove, or
lubrication is needed.
• Remove dust and then
lubricate.
*• Spring is abnormal
(missing, damaged or
fatigued).
• The claw ridge section of
the nail stopper is
abnormal (damaged, worn
or burrs).
• Check the operation of nail
stopper (A) and nail
stopper (B).
• Replace abnormal parts.
<Magazine section>
<Pushing lever>
• Magazine
• Check that a nail does not
catch on another nail in
the magazine.
• Check that a nail does not
catch on any part of the
magazine.
• Check the height of the
nail holder.
• Collate the nails correctly
and then reload the nailer.
• Remove burrs or
deformed parts. Replace
the parts.
• Adjust the height of the
nail holder correctly.
• Pushing lever
• Check the operation of the
pushing lever.
• Correct or replace the
parts.
<Output section: piston,
driver blade, etc.>
• Air pressure is too low.
• Adjust the air pressure to
12 to 23 bar (12 to 23
kgf/cm
2
, 170 to 320 psi).
*• Piston O-ring is abnormal
(worn or damaged).
• Replace the piston O-ring.
*• Piston bumper is
abnormal.
• Replace the piston
bumper.
• O-ring in the cylinder is
abnormal (removed,
deformed or damaged).
• Reassemble or replace
the parts.
1)
Nails cannot
be punched.
(continued)
• Driver blade is abnormal
(deformed, burrs or
damaged).
• Open the nail guide and
perform idle punching to
check that the driver blade
is returned.