Usage notes
5-19
HVM Navigator User's Guide - Migration
Migrating LPAR where EFI Shell is running
Do not have an LPAR where EFI Shell is running migrates. If you have an LPAR
migrate where EFI Shell is running, LPAR migration would fail.
Figure 5-2 Migration Progress window
Packet-lost during LPAR migration
While suspending an LPAR while the LPAR is migrating in Concurrent
Maintenance mode, packets sent to the LPAR with UDP communication are lost.
So, send the packets to the destination LPAR after finishing LPAR migration.
However, packets sent to the LPAR with TCP communication are sent
automatically again after finishing LPAR migration.
Memory high-load on guest OS on the LPAR to migrate
When memory writing rate is faster than memory transferring rate through a
migration path, an LPAR doesn’t migrate within a timeout period for LPAR
migration in Concurrent Maintenance mode.
Summary of Contents for NVM Navigator v03-07
Page 8: ...viii Contents HVM Navigator User s Guide Migration ...
Page 22: ...1 8 Overview HVM Navigator User s Guide Migration ...
Page 100: ...2 78 Usage environments HVM Navigator User s Guide Migration ...
Page 124: ...3 24 Migration procedures HVM Navigator User s Guide Migration ...
Page 138: ...3 38 Migration procedures HVM Navigator User s Guide Migration 10 Click Show Config button ...
Page 165: ...Migration procedures 3 65 HVM Navigator User s Guide Migration 4 Click Close button ...
Page 205: ...Migration procedures 3 105 HVM Navigator User s Guide Migration 3 Click OK button ...
Page 254: ...5 18 Usage notes HVM Navigator User s Guide Migration Figure 5 1 Migration Progress window ...
Page 258: ...5 22 Usage notes HVM Navigator User s Guide Migration Figure 5 3 HVM Console window ...
Page 266: ...5 30 Usage notes HVM Navigator User s Guide Migration ...
Page 310: ...6 44 Troubleshooting HVM Navigator User s Guide Migration ...
Page 314: ...7 4 List of icons HVM Navigator User s Guide Migration ...