4-12
Chapter 4
Safety Function
4.4.8
List of parameters
■
P
arameters for P1-FS
No.
Name
Range
Default
Memo
0-01
Motor nominal frequency
0.00 to 590.00Hz
50.00
0-02
Motor nominal speed
1 to 36000rpm (min
-1
)
1500
0-03
Motor Rated current
0.0 to 1000.0A
10.0
0-04
Motor pole
2/4/6/8/……/64
4
0-05
Inverter max frequency
0.00 to 590.00Hz
50.00
0-06
Inverter rated current ND
0.0 to 1000.0A
10.0
0-07
SFS select
11:STO-A / 12:STO-B / 21:SS1-A / 22:SS1-B / 31:SBC-A / 32:SBC-B
11
0-08
SFS reaction time
10 to 1000ms
100
0-09
Frequency data filtering
1 to 100ms
35
0-11
Safety Function Select Input 1
00:None / 01:STO-A / 02:SS1-A/ 03:SBC-A / 04:SLS-A / 05:SDI-A /
11:STO-B / 12:SS1-B / 13:SBC-B /14:SLS-B / 15:SDI-B
01
0-12
Safety Function Select Input 2
02
0-13
Safety Function Select Input 3
03
0-21
Safety Function Select Output 1
00:None / 01:STO-A monitoring / 02:STO-A completed /
03:SS1-A monitoring / 04:SS1-A completed / 05:SBC-A control /
06:SLS-A monitoring / 07:SDI-A monitoring / 08:SSM-A monitoring /
11:STO-B monitoring / 12:STO-B completed / 13:SS1-B monitoring /
14:SS1-B completed / 15:SBC-B control / 16:SLS-B monitoring /
17:SDI-B monitoring / 18:SSM-B monitoring / 21:Internal error /
31:test pulse(only S13)
01
0-22
Safety Function Select Output 2
02
0-23
Safety Function Select Output 3
05
0-31
Input arrangement 1
00:2NC / 01:1NC(path1) and 1NO(path2)
00:2NC / 01:1NC(path1) and 1NO(path2)
00:2NC / 01:1NC(path1) and 1NO(path2)
00
0-32
Input arrangement 2
00
0-33
Input arrangement 3
00
0-41
Output arrangement 1
00:2NC / 01:1NC(path1) and 1NO(path2)/02:2NO
00:2NC / 01:1NC(path1) and 1NO(path2)/02:2NO
00:2NC / 01:1NC(path1) and 1NO(path2)/02:2NO
00
0-42
Output arrangement 2
00
0-43
Output arrangement 3
00
0-51
Test pulse check 1
00:None / 01:Checking
00:None / 01:Checking
00:None / 01:Checking
00
0-52
Test pulse check 2
00
0-53
Test pulse check 3
00
0-61
Input 1 sensitivity
0.001 to 1.000s
0.001
0-62
Input 2 sensitivity
0.001 to 1.000s
0.001
0-63
Input 3 sensitivity
0.001 to 1.000s
0.001
0-71
Output 1 sensitivity
0.001 to 1.000s
0.001
0-72
Output 2 sensitivity
0.001 to 1.000s
0.001
0-73
Output 3 sensitivity
0.001 to 1.000s
0.001
0-81
Input 1 gap time
0.001 to 1.000s
0.1
0-82
Input 2 gap time
0.001 to 1.000s
0.1
0-83
Input 3 gap time
0.001 to 1.000s
0.1
0-91
Output 1 gap time
0.001 to 1.000s
0.001
0-92
Output 2 gap time
0.001 to 1.000s
0.001
0-93
Output 3 gap time
0.001 to 1.000s
0.001
Summary of Contents for P1
Page 2: ...The picture is an example of installing P1 FS to SJ P1 ...
Page 8: ...C 3 Index Memo ...
Page 10: ...1 2 Chapter 1 Safety Precaution Risk Memo ...
Page 12: ...2 2 Chapter 2 Introduction to the Safety Function Guide Memo ...
Page 62: ...7 2 Chapter 7 Commissioning Memo ...
Page 64: ...8 2 Chapter 8 Verification and Validation Memo ...
Page 68: ...10 2 Chapter 10 Maintenance Memo ...
Page 72: ...11 4 Chapter 11 Specification and Technical data Memo ...