4

OPERATION & INSTALLATION MANUAL FOR PC-LH3A

6

OPERATION

„

  When operating the controller, face the transmitter toward the receiver of the indoor unit and

press the switch for the required operation as described in the item '4. Sending Commands from
Controller'.

Ô

ATTENTION:

In case that two indoor units are installed side by side, the commands from the controller may
be received by both indoor units.  The function to identify each indoor unit not applicable.

7

INSTALLING ONTO THE WALL OR PILLAR

Ô

ATTENTION:

When the commands are sent by the controller hooked onto the wall, the receiver of the indoor
unit may not receive the commands.

1) Select the suitable place for handling and install the controller with the customer's acceptance.

Do not install the controller at the places as shown in the below.

   * where children can touch

   * where the air from the air conditioner is directly discharged

   * where there is oil vapor and the oil is dispersed

   * where the humidity is high

2) Pay attention to the following points in case that the controller is installed in a place where there is

medical equipment radiating electromagnetic waves.

a) Install the controller in a place where electromagnetic waves are not radiated directly toward

the electrical box of the indoor unit and the controller.

b) Keep a distance more than 3 meters away from the equipment radiating electromagnetic

waves, the receiver of the radio, etc. for prevention of the noise through the air.

c) In case that there is electric noise at the power source for the indoor unit, the treatment such

as providing a noise filter is required.

3) Do not install the controller in a place where generation, flowing, staying or leaking of flammable

gas is detected.

4) Install the controller in a place where there is a distance more than 30cm from the power supply

cable when installing the controller onto the wall.

5) Install the holding bracket (accessory) onto the wall by using screw (accessory) and attach the

controller to the holding bracket. Test Running by Controller

Summary of Contents for PC-LH3A

Page 1: ...on manual No realice la instalación de este equipo sin antes consultar este manual de instalación Bei der Installation unbedingt die Hinweise in der Installationsanleitung beachten Consulter notre manuel avant de réaliser une quelconque installation Realizzare l installazione seguendo quanto indicato in questo manuale Nao inicie os trabalhos de montagem sem consultar o nosso manual de montagem Udf...

Page 2: ......

Page 3: ...uerte ADVARSEL Farer eller farlig brug som KAN resultere i alvorlig personskade eller dødsfald WAARSCHUWING Gevaren of onveilige praktijken die ernstig persoonlijk letsel of de dood tot gevolg KUNNEN hebben VARNING Risker eller osäkra tillvägagångssätt som KAN leda till svåra personskador eller dödsfall ȆȇȅǼǿǻȅȆȅǿǾȈǾ ȀȓȞįȣȞȠȚ Ȓ İʌȚțȓȞįȣȞİȢ ʌȡĮțIJȚțȑȢ ȠȚ ȠʌȠȓİȢ ȂȆȅȇǼǿ ȞĮ ȑȤȠȣȞ ȦȢ ĮʌȠIJȑȜİıµĮ ıȠȕĮȡȑȢ ...

Page 4: ......

Page 5: ...it outdoor unit within approximately 3 meters from strong electromagnetic wave radiators such as medical equipment In case that there is electric noise at the power source for the indoor unit provide a noise filter Do not turn ON the power source unless the preparation for test running is completed Read this manual carefully before installation work for correct performance 2 BEFORE INSTALLATION AN...

Page 6: ...be started or stopped by pressing this switch Fan Speed Switch Press this switch to select the fan speed By repeatedly pressing the button the setting will change sequentially through HIGH MED and LOW Fan speed is fixed at low for dry operation Mode selection switch By repeatedly pressing the mode switch the unit cycles through the different operating modes in the order of HEAT DR COOL and FAN To ...

Page 7: ...ds again The transmitter of the controller has the vertical directivity to the receiver and the permissible angle for transmitting is within 50º However the capable distance for transmitting gets half when the transmitting angle is 50º and also get shorter in case that an electronic type light is used in the room NOTE The above figure shows the case of a 4 way cassette type indoor unit The figures...

Page 8: ... vapor and the oil is dispersed where the humidity is high 2 Pay attention to the following points in case that the controller is installed in a place where there is medical equipment radiating electromagnetic waves a Install the controller in a place where electromagnetic waves are not radiated directly toward the electrical box of the indoor unit and the controller b Keep a distance more than 3 ...

Page 9: ... OFF COOL COOL Me C Test Run Mode is under Operating 4 Operate the Test Run by pointing the transmitter towards the receiver of the indoor unit and press the RUN STOP switch When the commands are received by the indoor unit the lamp yellow of the receiver will come on briefly Check the commands are received well and the mode selected 3 is set correctly In the test run mode the red lamp RUN of the ...

Page 10: ...d apply the standard panels for wired control to other units In case of applying plural air panels for wireless control up to 2 air panels for wireless control can be used In case of applying two 2 air panels for wireless control the setting of main and sub receiver part is required Refer to the receiver kit installation manual 2 Perform wiring between indoor units by referring to the receiver ins...

Page 11: ...otary switch Setting ÔATTENTION In case that the setting of the rotary switch is not performed correctly an abnormal operation irregular run stop may occur when test running or actual operation 5 Check the Number of Indoor Units Connected Check the number of indoor units connected when test running The 7 segment indication of the receiver part shows the number of the indoor units connected in case...

Page 12: ......

Reviews: