background image

3.  Name of Parts

 Controller:

3

● 

This controller is used to send commands about operation mode, timer setting, etc. to the indoor unit.

 

Face the transmitter of the controller toward the receiver of the indoor unit and press the switch of required 

operation so that commands (by infrared rays) are sent to the indoor unit.

● 

The distance for transmitting is approximately 6 meters as a maximum.  (The capable distance for transmitting 

will get shorter in case that the transmitting angle is not vertical to the receiver or an electronic type light is 

used in the room, etc.)

● 

PC-LH3B is only available for the combination of the receiver kit and the indoor unit which are supported 

HIGH2 mode.

1 Step

2 Step

7 Step

Auto Swing

ON OFF

°C

Hi

Me

Lo

TIMER

MODE

RESET

TEMP.

FAN

LOUVER

CANCEL

OFF TIME

TIMER

SET

ON TIME

AUTO

HEAT

DRY

COOL

FAN

RUN/STOP

 Transmitter

  Point the transmitter towards the receiver of the indoor unit when sending

  commands.  The transmitting indication on the liquid crystal display flashes

  when sending commands.

 Transmitting Indication

 Liquid Crystal Display

  The set temperature, timer operation, position of air louver, operation mode, 

  air flow mode, etc., are indicated.  The fan speed setting “HIGH2” will not be

  shown on PC-LH3A.  The diagram of the display shown on the left is for

  explanation purposes only.  The display will differ during actual operation.

 Run/Stop Switch

  Operation of the unit can be started or stopped by pressing this switch. 

 Fan Speed Switch

  Press this switch to select the fan speed. By repeatedly pressing the button, 

  the setting will change sequentially through HIGH2, HIGH, MED and LOW. 

  (Fan speed is fixed at Low for dry operation.)

 

  O: Available

  X: Not available

 

HIGH2 is not indicated on PC-LH3A.

 Mode Selection Switch

  By repeatedly pressing the mode switch, the unit cycles through 

  the different operating modes in the order of HEAT, DRY, COOL and FAN. 

  To select auto operation, press the switch for more than 3 seconds. 

  If the switch is pressed again, it will return to FAN mode.

 Louver Angle Switch

  The airflow angle and auto-louver operation can be set by this switch. 

  When pressing the switch, the angle is changed in the following order. 

  (In cool or dry operation modes, steps 1-5 and Auto swing are available.)

 Temp. Switch

  The setting temperature can be adjusted using this switch.

 Timer Switches

  Four switches control the timer operation. 

  The set time can be changed by pressing “ON TIME” or “OFF TIME”  and is set

  by pressing the “SET” switch.  Timer operation can be cancelled using “CANCEL”.

 Reset Switch

  (1) Press RESET to turn off the filter indicator lamp after filter cleaning.

  (2) If the unit is stopped abnormally due to protection devices etc., 

   press the RESET switch to cancel the control stoppage

   after the cause of the abnormality has been removed.

PC-LH3A

PC-LH3B

Hi 2 (HIGH2)
Hi    (HIGH)
Me   (MED)
Lo    (LOW)

X

O
O
O
O

O
O
O

Hi 2

The figure shows

for PC-LH3B.

Model

Fan

Speed

Summary of Contents for PC-LH3A

Page 1: ...m the test run whether there is abnormality or not after the installation work is completed The usage and the maintenance should be explained to a user according to Installation Maintenance Manual of the indoor unit Describe to keep this installation manual also l It is assumed that this kit will be installed and serviced by English speaking people If this is not the case the customer should add s...

Page 2: ...the contents and the number of the parts Name Q ty Remark Wireless Remote Control Switch Controller 1 For Operation Control Holding Bracket 1 For Controller Battery AAA 1 5V Dry Cell 2 For Power Source of Controller Screw 2 For Fixing Holding Bracket onto Wall Slide the cover in the arrow direction with pushing AAA Batteries 2 Do not turn ON the power source unless the preparation for test running...

Page 3: ...g actual operation Run Stop Switch Operation of the unit can be started or stopped by pressing this switch Fan Speed Switch Press this switch to select the fan speed By repeatedly pressing the button the setting will change sequentially through HIGH2 HIGH MED and LOW Fan speed is fixed at Low for dry operation O Available X Not available HIGH2 is not indicated on PC LH3A Mode Selection Switch By r...

Page 4: ...g gets half when the transmitting angle is 50o and also get shorter in case that an electronic type light is used in the room NOTE The above figure shows the case of a 4 way cassette type indoor unit The figures for other models are different partially LCD Liquid Crystal Display Indication When viewed from certain angles the LCD can be difficult to read The viewing angle ranges from an optimal of ...

Page 5: ...oor Units Installed Side by Side NOTE This function is required to set at the receiver side It shall be set according to the installation manual of the receiver kit or the indoor unit Setting of Identifying of Indoor Units Installed Side by Side 1 Press and hold ON TIME switch and OFF TIME switch of the wireless remote control switch simultaneously for 3 seconds The b is indicated on the liquid cr...

Page 6: ...tion to the following points in case that the controller is installed in a place where there is medical equipment radiating electromagnetic waves 1 Install the controller in a place where electromagnetic waves are not radiated directly toward the electrical box of the indoor unit and the controller 2 Keep a distance more than 3 meters away from the equipment radiating electromagnetic waves the rec...

Page 7: ...In the test run mode the red lamp RUN of the receiver is turned ON and the green lamp TIMER flashes 0 5 seconds ON 0 5 seconds OFF 2 And then set off timer for 2 hours NOTES 1 In the case that the lamp yellow does not turn ON the controls may not have reached the receiver Send the commands again 2 2 In the case of RPK model TIMER lamp is turned ON without flashing 5 Adjust the angle of the air lou...

Reviews: