Related Messages
(PJ400 only)
When the unit’s power is on, messages such as those shown below may be displayed. When any such message
is displayed on the screen, please respond as described below.
Although these messages will be automatically disappeared around several minutes, it will be reappeared every
time the power is turned on.
Message
Description
To maximize
performance, lamp
replacement is
recommended.
After the lamp running reaches 2000 hours, the warning message is displayed,
but it won't shut the unit off.
The message displays for 30 seconds when the PJ is turned on. If we push any
button while displaying the message, the message disappear.
CLEAN THE AIR FILTER
POWER OFF FIRST,
THEN CLEAN THE AIR FILTER.
AFTER CLEANNIG THE AIR
FILTER,
RESET THE FILTER TIMER.
The time the fi lter timer has counted has reached 100 hours.
Please clear or change the air fi lter by referring to the section "Air fi lter". After caring
for the air fi lter, Please be sure to reset the fi lter timer.
NO INPUT IS DETECTED
ON ***
There is no input signal.
Please confi rm the signal input connection, and the status of the signal source.
SYNC IS OUT OF RANGE
ON *** fH *****kHz fV *****Hz
The horizontal or vertical wavelength of the inputted signal is outside of the
response parameters of this unit.
Please confi rm the specs for this unit or the signal source specs.
CHECK THE AIR FLOW
The internal portion temperature is rising.
Please turn the power OFF, and allow the unit to cool down at least 20 minutes.
After having confi rmed the following items, please turn the power ON again.
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
• If the same indication is after the treatment, please set the HIGH at FAN SPEED
of the item SERVICE of the OPTION menu.
CLEAN THE AIR FILTER
POWER OFF FIRST,
THEN CLEAN THE AIR
FILTER.
AFTER CLEANING THE AIR
FILTER,
RESET THE FILTER TIMER.
A note of precaution when cleaning the air fi lter.
Please immediately turn the power OFF, and clean or change the air filter by
referring to the “Air Filter” section of this manual. After you have cleaned or
changed the air fi lter, please be sure to reset the fi lter timer.
NOTE
• A lamp has a fi nite product life. Lamps are characterized by the fact that, after long hours of
usage, a lamp will no longer light up, or the lamp will break or burst, etc. Please be aware, however, that
among lamp types, there are major differences in product lifetimes; a lamp may thus fail to light even prior
to the lamp life.
Summary of Contents for Performa CP-RS55
Page 27: ... CP RS55 only ...
Page 28: ... for CP RS55 only ...
Page 36: ...36 8 Disassembly diagram ...
Page 37: ...37 ...
Page 54: ...54 12 Connector connection diagram Connector connection diagram C12S ...
Page 57: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A POWER UNIT CIRCUIT C12S ...
Page 58: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 1 C12S ...
Page 59: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 2 C12S ...
Page 60: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 3 C12S ...
Page 61: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 4 C12S ...
Page 62: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 5 C12S ...
Page 63: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 6 C12S ...
Page 64: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 7 C12S ...
Page 65: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 8 C12S ...
Page 66: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 9 C12S ...
Page 67: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 10 C12S ...
Page 68: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A PWB assembly MAIN 11 C12S ...