9. Troubleshooting Guide
9-1
●
Troubleshooting Guide
A fault message is
displayed.
Pressing a key does not
invoke its predefined
operation.Or the key is
not accepted.
¡
Select the "same as
current time" option.
(
See Section 4.3, Setting
the Date and Time.
)
¡
Turn OFF the power
switch. Ensure that
power is supplied the
power outlet, and then
connect the power plug to
the power outlet.
See Section 8, If a Warning Condition/Fault Occurs.
If the printer does not normally start up, perform the following checks before you
jump to the conclusion that the printer is defective.
Phenomenon
Check
Solution
The power does not turn
ON at the press of the
power ON/OFF switch.
The printer does not
become ready for
printing at pressing the
Start up key.
¡
Check that the power
plug is properly connected
to a power outlet.
¡
Check that electrical power
is supplied to the
employed power outlet.
¡
Check for an ink stream
ejection from the nozzle.
¡
Check whether the
ejected ink stream enters
the gutter hole.
¡
Stop the ink ejection
sequence by pressing
the Shut down key.
¡
See Section 7.6,
Correcting a Bent Ink
Stream and Clogged
Nozzle, and correct the
problem.
CAUTION
¡
If the above remedies do not restore the printer to normal,
stop using the printer, disconnect the power plug from the
power outlet, and contact your Hitachi distributor.
■
Report the following to your local source or service company:
1. TYPE-FORM (model number)
IJ printer
Model PXR-
2. SER. No. (serial number)
PXR
3. Failure description
In detail
4. Organization name (department and section names included), name of person
in charge, and telephone number
* The model number and serial number are marked on the nameplate that
is attached to the right-hand side of the printer.
¡
See Section 5.4, Calibrating the Touch Screen
Coordinates.
¡
See Section 1.2.10, Protection Sheet for touch panel.
The calendar time is not
correctly printed.
¡
Check that "clock stop" is
not selected from the
date/time setup screen.
(
See Section 4.3, Setting
the Date and Time.
)
Entering a remote
control signal will not
cause the system to
function.
¡
Is the confirmation
window on?
¡
Is the Touch screen
coodinate on?
¡
Is the circulation control
screen on?
¡
Close the window or
display another screen,
then enter a signal
again.
Summary of Contents for PXR-D
Page 319: ...3S23L1307 3B PXR D E7 HEC ...