Excitation frequency
JP-T71
JP-K72
1-36
●
Connection of signals
28.1kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
68.9kHz
Ink Type
JP-K26
JP-B27
JP-G27
JP-K31A
68.9kHz
68.9kHz
68.9kHz
JP-K27
JP-R27
JP-K33
68.9kHz
68.9kHz
90.9kHz
74.0kHz
90.9kHz
JP-Y37
68.9kHz
68.9kHz
¡
The printing scan count maximum value is dependent on the printed character width
and conveyor maximum speed and calculated using the following equation.
Substitute the nozzle diameter suited for the model you are using for item d.
Printing scan count maximum value[kHz]
1
60
horizontal dot count
−
1
character width[mm]
−
d[mm]
×
……
(Equation 1)
¡
Using Equation 2, check whether the printing scan count maximum value determined
by Equation 1 can be followed by the IJ printer printing speed.
Excitation frequency(f)
(Vertical dot count + character width s 1) x (ink drop use percentage)
[kHz]
>
¡
The excitation frequency (f) value varies with the ink type employed.
65
μ
m Nozzle Machine 40
μ
m Nozzle Machine 100
μ
m Nozzle Machine
28.1kHz
28.1kHz
28.1kHz
JP-K60
JP-F63
JP-T64
JP-K65
80.0kHz
JP-R65
JP-K61
JP-K62
JP-K67
90.9kHz
90.9kHz
90.9kHz
90.9kHz
28.1kHz
JP-K28
68.9kHz
JP-K68
JP-K69
68.9kHz
JP-K70
68.9kHz
68.9kHz
=
conveyor maximum speed[m/min]
×
printing scan count maximum value[kHz]
……
(Equation 2)
nozzle diameter
65
μ
m
40
μ
m
100
μ
m
d
0.3
0.2
0.5
68.9kHz
JP-T75
68.9kHz
JP-R76
68.9kHz
JP-K84
68.9kHz
JP-K77
68.9kHz
JP-E78
68.9kHz
JP-F80
68.9kHz
JP-K81
68.9kHz
JP-B82
68.9kHz
JP-K86
68.9kHz
JP-K87
Summary of Contents for PXR-D
Page 319: ...3S23L1307 3B PXR D E7 HEC ...