background image

1. In order to disassemble and repair the

unit in question, be sure to disconnect
the power cord plug from the power
outlet before starting the work.

2. If it is necessary to replace any parts, they should be replaced with respective genuine parts for the unit, and the

replacement  must be effected in correct manner according to the instructions in the Service Manual of the unit.

3. After completion of repairs, the initial state should be restored.
4. Lead wires should be connected and laid as in the initial state.
5. Modification of the unit by the user himself should absolutely be

prohibited.

6. Tools and measuring instruments for use in repairs or inspection should be accurately calibrated in advance.

7. In installing the unit having been repaired, be careful to prevent the occurrence of any accident such as electrical

shock, leak of current, or bodily injury due to the drop of any part.

8. To check the insulation of the unit, measure the insulation resistance between the power cord plug and grounding

terminal of the unit.
The insulation resistance should be 1M

Ω

or more as measured by a 500V DC megger.

9. The initial location of installation such as window, floor or the other should be checked for being safe enough to

support the repaired unit again.
If it is found not so strong and safe, the unit should be installed at the initial location after reinforced or at a new location.

10. Any inflammable object must not be placed

about the location of installation.

11. Check the grounding to see whether it is proper

or not, and if it is found improper, connect the
grounding terminal to the earth.

SAFETY  DURING  REPAIR WORK

First, I must disconnect
the power cord plug
from the power outlet.

If the contacts of electrical parts are

defective,  replace  the electrical parts

 without  trying  to repair  them.

DANGER

 1

Summary of Contents for R-Z570ARU7

Page 1: ...N MODEL R Z570ARU7 6 9 SPECIFICATIONS TYPE DOUBLE BIG 2 DOOR MODEL R Z570ARU7 POWER SOURCE 1Ø 220 240V 50Hz TOTAL INPUT W 186 220 TOTAL CURRENT A 1 40 1 50 NET 475L GREECE W 740 H 1795 D 710 NET WEIGHT Kgs 81 REFRIGERATOR H C P T SERVICE MANUAL DIMENSIONS mm MAR 08 VOLUME 570L No 1537 R Z570ARU7 PWH ...

Page 2: ...such as electrical shock leak of current or bodily injury due to the drop of any part 8 To check the insulation of the unit measure the insulation resistance between the power cord plug and grounding terminal of the unit The insulation resistance should be 1MΩ or more as measured by a 500V DC megger 9 The initial location of installation such as window floor or the other should be checked for bein...

Page 3: ...G CAPACITOR NO RUNNING CAPACITOR NO REFRIGERATOR THERMOSTAT RFA3700801 REFRIGERATOR CHARGING 135 g TEMPERATURE FRESH FOOD DIAL CONTROL FREEZER DIAL DEFROSTING WAY HEATER DEFROSTING INITIATION F AUTOMATIC R AUTOMATIC SYSTEM TERMINATION F AUTOMATIC R AUTOMATIC EVAPORATION FORCED TABLE TOP NO CRISPER SLIDE OUT FREEZER THERMOSTAT R Z570ARU7 2 ...

Page 4: ...EPER DOOR MULTI CHILLER SHELF R ICE TRAY EGG STORAGE CAPACITY TURN POCKET POLYURETHANE INSULATOR OTHER FEATURE FREEZER ICE CUBE BOX SHELF F YES YES YES YES 3 1 PLASTIC SHELF R Z570ARU7 YES YES 3 GLASS SHELF 2 14 YES ...

Page 5: ...OMPRESSOR FL1462SU RCA3033901 PHASE SINGLE PHASE RATE VOLTAGE V 220 240V RATE FREQUENCY Hz 50Hz POLE NUMBER 2 CONNECTION M C 17 4 S C 35 6 Ω STARTING CURRENT A 6 56A R Z570ARU7 RESISTANCE VALUE 75 C 4 MAIN COIL STARTING COIL M S C ...

Page 6: ...MODEL R Z570ARU7 5 ...

Page 7: ...1 2 7 8 9 10 13 15 16 18 17 11 14 12 3 4 6 5 6 ...

Page 8: ...19 55 56 57 59 60 58 46 68 42 45 51 50 23 22 21 20 27 28 26 25 62 61 65 63 52 31 30 34 35 38 39 37 36 32 33 53 54 67 66 67 86 41 40 74 44 43 95 7 ...

Page 9: ...89 90 92 91 94 93 87 88 8 ...

Page 10: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...

Page 11: ...R Z570ARU7 PWH No 1537 HITACHI ...