– 131 –
13. Timer lamp blinking: blinking 12 times
[Situation] The timer blinks 12 times and the product will not run.
[Estimated failure locations]
・
Erroneous connection in the indoor-outdoor connection line (F cable)
・
Wire break or poor insertion of the indoor-outdoor connection line (F cable)
・
Electrical parts in the outdoor unit
・
Communication error due to noise in other home electronics
※
This does not constitute a failure in the air-conditioner.
[Cautions]
・
When lines A and B of F cable are erroneously connected (crossed), the product may not
enter self-diagnosis display mode. If the self-diagnosis memory stores data about "timer
lamp blinked 12 times", then, just in case, check if the F cable is not erroneously connected.
・
Detecting this failure mode turns off the power relay 3 minutes later and blocks the power
supply to the outdoor unit.
[Diagnosis flow]
Initiating troubleshooting
Is the F cable connection free from errors?
Yes
Yes
Yes
Yes
No
No
No
No
Correct the F cable connection.
Is the CN30 securely inserted into
the outdoor board?
Correct the connector.
Press the START/STOP button on the remote control
unit and start the product.
Are terminals A and B of the terminal board of the
electrical parts of the outdoor unit subjected to
220V AC?
※
Take measurements within 3 minutes after remote
control operation.
Check the electrical parts of the
outdoor unit.
Are terminals A and B of the terminal board of the electrical
parts of the indoor unit subjected to 220V AC?
※
Take measurements within 3 minutes after remote control
operation.
Double-check the F cable for erroneous connection,
wire break and poor insertion, and correct the
nonconforming parts.
Replace the "indoor electrical parts".
14. Timer lamp blinking: blinking 13 times
[Situation] The timer lamp blinks 13 times and the product will not run.
[Estimated failure location]
・
EEPROM, microcomputer
[Diagnosis flow]
Replace the "indoor electrical parts".
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...