– 134 –
The LD301 b
links 10 times
.
Po
w
er supply v
oltage error
The LD301 b
links 7 times
.
Ther
mistor abnor
mality
The LD301 b
links 6 times
.
OH ther
mistor heat-up
The LD301 b
links 5 times
.
Ov
er
load lo
w
er limit cut
Is there 220
V A
C
betw
een
ter
minal boards A and B?
187
V A
C
or less
, 253
V A
C
or more
Chec
k the po
w
er supply
.
Is there a v
oltage of 264-358
V DC?
F
or measur
ing points
, see the instr
uction plate on the lid of the
electr
ical par
ts
.
Abnor
mal
Abnor
mal
Abnor
mal
Abnor
mal
Abnor
mal
Replace the outdoor electr
ical par
ts
(in the case of an abnor
mality in the full
wa
ve/doub
le v
oltage rela
y or rectification
circuit).
187-253 V
A
C
Replace the outdoor electr
ical par
ts
(in the case of an abnor
mality in the
vo
ltage detection circuit).
Chec
k f
or loose or poor
ly inser
ted ther
mistors
.
Connect the ther
mistors
.
Chec
k the ther
mistors f
or wire breaks and shor
t-circuits
.
Replace an
y abnor
mal
ther
mistors
.
Replace the outdoor electr
ical par
ts
(in the case of an abnor
mality in the ther
mistor
detection circuit).
Chec
k the OH ther
mistor f
or wire breaks and shor
t-circuits
.
Replace the OH ther
mistor
.
Chec
k if the OH ther
mistor is not loose or poor
ly inser
ted.
Connect the OH ther
mistor
.
Nor
mal
Nor
mal
Nor
mal
Nor
mal
Nor
mal
Re
vie
w the freezing cycle
.
(Refr
iger
ant leakage or other
reason is conceiv
ab
le
.)
If re
vie
wing the freezing cycle does not
correct the prob
lem, replace the outdoor
electr
ical par
ts (in the case of an
abnor
mality in the ther
mistor detection circuit).
The OH ther
mistor has
detected heat-up in the compressor
.
When cooling:
Is the heat e
xchanger of the outdoor unit clogged up?
Is there shelter around?
When heating:
Is the heat e
xchanger or filter of the indoor unit
clogged up?
Is the freezing cycle abnor
mal?
Is the freezing cycle abnor
mal?
Remo
ve the cause of the prob
lem.
Correct the abnor
mal location.
Since the compressor load w
as hea
vy
, the
product w
as stopped.
Ye
s
No
Ye
s
Ye
s
Ye
s
No
No
No
No
No
Ye
s
Ye
s
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...