1
2
The air conditioner detects indoor temperature and humidity
. Once the temperature and humidity reaches to a
level conductive to mold growth, the dehumidifying and stainless plasma air purifying operations automatically
start.
Press
the
(FUNCTION SELECTOR) button until
(MOLD MONIT
OR) blinks.
While
(MOLD MONIT
OR) is blinking, point the remote controller
towards
the unit and press the
(ON/OFF) button.
•
Preset the mold monitor operation.
•
During the mold monitor operation,
(ON/OFF)
and
(MONIT
OR)
indicators on the indoor unit turns on.
Press the
(FUNCTION SELECT
OR) button again until
(M
O
L
D MONIT
OR) blinks.
While
(MOLD MONIT
OR) is blinking, point the remote controller
towards the unit and press the
(ON/OFF) button.
•
A
short beep sounds and
(MOLD MONIT
OR) indicator
turns
of
f
on
the remote controller
.
•
The
(MONIT
OR) indicator on the indoor unit turns of
f.
CANCEL
•
Mold monitoring operation is a preset function. Even if mold monitoring mode is preset, the actual operation
will be performed only when the detected temperature and humidity has reached the level conducive to mold
growth.
•
The setting of mold monitoring mode is valid for 2 weeks from the last remote control operation.
(If any remote control operation is performed while
(MOLD MONIT
OR) is set, the preset mold monitoring
mode is valid for 2 weeks from such remote control operation.)
Once the above mentioned 2 weeks have elapsed, the
(MONIT
OR) indicator on the indoor unit turns
of
f.
(However
,
(MOLD MONIT
OR) indication on the remote controller remains on. If the
(MONIT
OR)
indicator on the indoor unit is of
f, please reset or cancel the mold monitoring mode.)
•
When mold monitoring mode is set, the fan operation is performed for approximately 3 minutes once every
approximately 20 minutes and the room temperature and humidity are detected.
(The movable panel and horizontal air deflector remain closed when temperature and humidity are
detected.)
•
In the first cycle of mold monitoring operation, dehumidifying operation is performed for 4 hours consecutively
if the detected temperature and humidity are 10°C and more and 70% and more, respectively
. From the
second cycle onwards, dehumidifying operation is performed if the detected temperature and humidity reach
the above mentioned level and will stop once the humidity has gone down.
•
For the duration of 20 minutes after mold monitoring operation temporarily stops, the mold monitoring operation
is not performed immediately even if mold monitoring mode remains set and the humidity exceeds 70%.
•
There is no function to remove mold that has grown.
– 23 –
ENGLISH
MOLD MONITOR OPERATION
10_14SH3_OM.indd 2310_14SH3_OM.indd 23
2012-2-21 14:51:462012-2-21 14:51:46
60°
15°
10°
50°
ADJUSTING THE VER
TICAL AIRFLOW DIRECTION
Please operate with the remote controller
. (Moving by hands may cause malfunction.)
Cooling
operation
Heating
operation
Dehumidifying/
Dry Cool operation
About
About
About
Set automatically
•
Air conditioner automatically set to the suitable
angle for each operation (Horizontal air deflector
only
.
The angle of the vertical air deflector is set to
the front). Usually vertical airflow direction control
is not required.
•
If room temperature and humidity continue to be
high during cooling, dehumidifying or dry cool
operation, the angle of horizontal air deflector may
change to prevent dripping of condensed water
.
Swing
angle
About
Horizontal
V
ertical airflow swing
•
When the
(VER
TICAL
AIRFLOW) button is pressed,
a short beep sounds and the vertical air deflector repeats
swinging.
•
When the air conditioner stops operation, the swing of the
vertical air deflector also stops and the air outlet closes.
•
If the operation resumes, the vertical air deflector is
automatically set to the suitable angle for each operation.
•
Even if the swing mode is set, the vertical air deflector may
stop swinging depending on the room temperature and
humidity
. (Page 25)
(It may take approximately 10 seconds for the air deflector
to start moving.
This is due to the checking operation to set
the air deflector to the correct angle.)
V
ertical air flow of your preference
•
T
o set the vertical airflow direction to your desired angle, press the
(VER
TICAL
AIRFLOW) button to move the vertical air deflector
, and press the
(VER
TICAL
AIRFLOW) button again to stop air deflector at your desired angle.
Press the
(VER
TICAL
AIRFLOW) button.
•
A
short beep sounds and the vertical air deflector repeats swinging.
(V
ertical airflow swing)
Press the
(VER
TICAL
AIRFLOW) button again at your preferred angle.
•
The swing stops at the position where the button is pressed.
•
The air outlet closes if the operation stops. The horizontal air deflector will return to
the preset position when the operation resumes.
•
If the operation mode is changed, the horizontal air deflector will automatically be
set to the proper angle suitable for the newly set mode.
CAUTION
DO not operate long hours with cooling, dehumidifying, dry operation, airflow swing operation nor
the vertical air deflector in downward state.
Some dew may form on the vertical air deflector and drop which may wet your furniture.
ENGLISH
DEUTSCH
FRANÇAIS
ITALIANO
SPANISH
PORTUGUÊS
∂ÏÏËÓÈο
РУССКИЙ
– 24 –
10_14SH3_OM.indd 24
10_14SH3_OM.indd 24
2012-2-21 14:51:462012-2-21 14:51:46
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...