The movements of the left and right air deflectors displayed in the remote controllers
are not synchronous with movements of the actual air deflectors.
ADJUSTING THE HORIZONT
AL AIRFLOW DIRECTION
Adjust the horizontal airflow direction
•
The angle of horizontal airflow direction is set to the front at the
time of
purchase.
•
Every time the button is pressed, the mode of the horizontal air deflector
changes as below
.
•
A
short beep sounds and the angle of the horizontal air deflector changes.
Front
Horizontal
swing
preferred angle
Horizontal angle of your preference
•
•
T
o set the horizontal airflow direction to your desired angle, move the
horizontal air deflector and press the
(HORIZONT
AL
AIRFLOW) button
again to stop air deflector
’s movement once it has reached your desired
angle.
Press the
(HORIZONT
AL
AIRFLOW) button again to fix your preferred
angle during horizontal airflow swing.
•
Fan speed may be increased depending on the angle of the horizontal air
deflector
.
•
Even if the horizontal airflow direction has been adjusted to your desired
angle, the angle of horizontal air deflector may change in the event the room
temperature and humidity continue to be high during cooling, dehumidifying
or dry cool operation.
The angle will change back to your desired angle once
the temperature and humidity have been lowered by the air conditioning
operation.
CAUTION
Do not operate long hours with cooling, dehumidifying, dry cool operation and horizontal airflow swing
operation.
Some dew may form on the horizontal air deflector and drop which may wet your furniture.
In the following cases, the swing stops even when vertical swing and horizontal swing are set.
In Heating operation
In Dehumidifying operation
In Dry Cool operation
•
During preheat operation.
•
During defrost operation.
•
When the room temperature
reaches the temperature which
had been set.
•
When the humidity is reached
to the humidity which has been
set.
•
When the room temperature is
below 1°C.
•
When the temperature is below
the temperature which has been
set and the operation is stop.
The movement scope of the left/right air deflectors are set to the following
5 positions:
– 25 –
ENGLISH
10_14SH3_OM.indd 2510_14SH3_OM.indd 25
2012-2-21 14:51:472012-2-21 14:51:47
TIMER PRESET OPERATION
How to preset the timer
1
3
2
3 types of timers,
(OFF
TIMER)
(ON
TIMER),
(OFF
TIMER) and
(ON
TIMER) are available. Only
one of these timers can be preset at a time.
Operation mode, temperature, humidity and fan speed, etc. must be set before setting the timer
.
For
(OFF TIMER) preset
•
When
(OFF
TIMER) is set, the operation stops at the preset time.
For
(ON TIMER) preset
•
When
(ON
TIMER) is set, the operation starts so that the preset temperature is reached at the preset time.
•
The air conditioner starts operation a maximum of 60 minutes before the preset time, depending on conditions
including room temperature and preset temperature.
How to preset the
(OFF TIMER)
(ON TIMER)
(For example: When setting the timer to stop operation at 10:30 p.m. and your desired temperature is reached at
7:00 a.m.)
•
The timer with earlier preset time will function first, based on the time at which the timer is set.
Press the
(OFF
TIMER) button.
•
(OFF
TIMER) blinks.
•
0:00 a.m. or the previous preset
time is displayed.
Press the
(TIMER)
button to set the time.
•
T
ime can be set in increments
of 10 minutes.
•
The time can be fast-forwarded
by continuously pressing the
button.
T
ime is incremented
T
ime is decremented
Press the
(PRESET)
button.
•
A
short beep sounds and the
(OFF
TIMER) is set.
•
(OFF
TIMER) indication
stops blinking and lights up.
(TIMER SET) will be
displayed.
•
The
(TIMER) indicator on the
indoor unit lights up.
•
T
o change the preset time for
(
OFF
TIMER),
return
to
procedure
and press the
(OFF TIMER)
button.
10_14SH3_OM.indd 26
10_14SH3_OM.indd 26
2012-2-21 14:51:472012-2-21 14:51:47
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...