This is for filter cleaning operation check.
•
In basic air-conditioner operation (cooling operation etc.), the filter cleaning operation
will not start even when the
(MANUAL CLEAN) button on the remote controller is
pressed.
(
(CLEAN) indicator lit for 1 second/off for 1 second, for 10 seconds)
•
During filter cleaning operation or within 5 minutes after the operation, even when
the
(MANUAL CLEAN) button on the remote controller is pressed, the filter
cleaning operation will not restart to protect the device.
(
(CLEAN) indicator lit for 1 second/off for 1 second, for 10 seconds)
•
Is “filter cleaning operation prohibited” being set?
Please return to the filter cleaning operation setting.
(
(CLEAN) indicator lit for second/off for 1 second, for 10 seconds)
•
Are micro mesh stainless filter
, dust catcher
, filter cleaning wiper
, wiper cover correctly
installed?
(
(CLEAN) indicator lit for 4 seconds/off for 1 second)
•
Filter cleaning is not performed if the air conditioner operation is stopped by Sleep
T
imer or Of
f
T
imer function. However
, if the air conditioner is stopped by Sleep
T
imer or Of
f
T
imer every time, filter cleaning will be performed approximately once
a week.
•
A
whirring motor noise is generated due to driving of the cleaning unit.
•
A
clapping noise is generated when the dust catcher collects the dust swept by the
cleaning unit.
•
A
clapping noise is generated when the dust catcher is turned over by the cleaning
unit.
•
A
sweeping sound is generated when the cleaning unit sweeps the dust.
•
After the filter cleaning wiper maintenance, is the cleaning unit return to the right
end part using the remote controller?
•
Are micro mesh stainless filter
, dust catcher
, filter cleaning wiper
, wiper cover correctly
installed?
(
(CLEAN) indicator lit for 4 seconds/off for 1 second)
TROUBLESHOOTING
FIL
TER CLEANING OPERA
TION
Filter cleaning is
performed after
the power is
turned on (after
the plug-in or after
the circuit breaker
is switched on
after power failure)
Filter cleaning
operation does not
start
(
(CLEAN)
indicator blinks
or lit and dim
repeatedly)
Noise occurred
during filter
cleaning operation
Cleaning unit
stops halfway
•
Filter may not be cleaned evenly depending on the environment in which the air
conditioner is used.
T
o solve this problem, clean the micro mesh stainless filter
.
•
Depending on dust amount, the micro mesh stainless filter may not be completely
cleaned by manual filter cleaning operation performed at your preferred time while
filter cleaning operation is prohibited.
Micro mesh
stainless filter is
still dirty
– 41 –
ENGLISH
10_14SH3_OM.indd 41
10_14SH3_OM.indd 41
2012-2-21 14:51:582012-2-21 14:51:58
TROUBLESHOOTING (continued)
Anti-mold
wasabi cassette
Dust box
ANTI-MOLD W
ASABI CASSETTE
•
Anti-mold elements with wasabi aroma prevents mold growth inside the dust box in which the dust collected
by filter cleaning operation is kept.
Although only a trace amount of anti-mold elements is released, there may
be wasabi smell in the room depending on the environment in which the air conditioner is used. If you feel this
smell is unpleasant, block one of the anti-mold element outlets with a commercially available adhesive tape. If
this measure is taken, the amount of anti-mold element to be released will be reduced and the anti-mold ef
fect
will also be less accordingly
.
T
o prevent mold growth, frequent cleaning of the dust box is recommended.
Outlet (2 places)
The gap made on
the side surf
ace
Bloc
k one of the outlets with an
adhesiv
e tape (Either one of 2
outlets)
•
Do the batteries need replacement?
•
Is the polarity of the inserted batteries correct?
•
Is the power plug inserted properly?
•
Is the fuse blown out or circuit breaker tripped?
•
Is there a blackout? (Operation remains idle after a blackout.)
•
Is the micro mesh stainless filter blocked with dust?
•
Is the set temperature suitable?
•
Have the vertical air deflector been adjusted to the correct positions according to
the operation mode selected?
•
Are the air inlets and air outlets of indoor and outdoor units blocked?
•
Is the fan speed “LOW” or “SILENT”?
•
Check “filter cleaning operation”.
PLEASE CHECK THE FOLLOWING BEFORE SER
VICE
Signal cannot be
received
(Remote controller
display is dim or
blank)
Operation does
not start
Does not cool well
Does not heat well
(CLEAN)
indicator blinks
– 42 –
10_14SH3_OM.indd 42
10_14SH3_OM.indd 42
2012-2-21 14:51:582012-2-21 14:51:58
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...