DEHUMIDIFYING OPERA
TION (continued)
Auto
Dehumidifying
Operation mode
In this situation
Operating mechanism
•
In
damp
weather
•
In most of the cases, the room temperature at the time the button is
pressed becomes the preset temperature.
(
When room temperature is below 12
°C, set 13°C. When it is
13°C~22°C, set +2°C. When it is below 23°C~26°C, set room
temperature. When it is above 26°C, set 26°C)
•
T
arget humidity is around 50~60%. If the humidity becomes lower than
the target value, operation stops. If it becomes higher than the target
value, operation resume.
•
The operation mode may automatically be switched to cooling or
heating for temperature control. (Refer to table below)
•
T
o dry the
laundry
quickly
•
Detects outdoor temperature, room temperature and humidity to
automatically select the most suitable combination of heating and
powerful dehumidifying operations.
•
This operation is performed together with stainless plasma air purifying
operation.
•
Priority is given to laundry drying.
Be sure use this mode when no one is in the room as the room
temperature and humidity will be high temporarily
.
•
3-hour timer function is used for this operation mode.
•
When
controlling
condensation
formed on
windows in
winter time
•
T
o control the condensation, priority is given to the operation for
lowering humidity
.
Therefore, the room temperature goes down in
this operation mode.
The operation stops if the room temperature
becomes 1°C or below
.
•
2-hour timer function is used for this operation mode.
Condensation
Control
Quick Laundry
•
Be careful when condensation control operation is performed if the outside temperature is low as it will lower the
room temperature.
•
(OFF
TIMER) and
(ON
TIMER) (page 26), which are to be set using clock function, are not available during
dehumidifying (quick laundry and condensation control modes) operation. However
, the timer (for 30 minutes
and 1-9 hours) can be set for quick laundry and condensation control modes with the
(SLEEP) button.
•
T
o set to your desired temperature and humidity while executing dehumidifying, it is recommended to use manual
dehumidifying function. (Page 17)
•
If you do not wish room temperature to be too high when drying the laundry
, use the preference (Powerful) mode
instead of quick laundry mode. (Page 18)
The operation mode may automatically be switched to cooling or heating for temperature control.
At this time, the room humidity may vary by approximately 10%.
Heating
operation
Dehumidifying operation
Operation
stop
Cooling
operation
About 3
°
C
Approx. 3°C if outside temp. is
below approx. 32°C.
Approx. 1°C if outside temp. is
above approx. 32°C.
Room temperature set
Current room temperature
1ºC
COOLING OPERA
TION
Press the
(COOL) button to start cooling operation.
Press the
(COOL) button.
•
Adjust the room temperature and fan speed to your preference.
T
emperature range between 16°C~32°C can be set.
Press the
(ST
OP) button.
•
A
short beep sounds and cooling operation stops.
ST
OP
– 15 –
ENGLISH
18SH3_OM.indd 1518SH3_OM.indd 15
2012-2-21 14:45:282012-2-21 14:45:28
•
If you want to set the desired temperature and humidity during dry cool operation, we recommend
you use the manual cooling operation. (Page 17)
ST
OP
DR
Y COOL OPERA
TION
When you operates cooling operation with the dry function,
press the
(DR
Y
COOL) button, the air conditioner
automatically sets temperature and humidity in dry cool mode.
Press the
(DR
Y
COOL) button.
•
Adjust the room temperature and fan speed to your
preference.
•
Every time you press the
(ROOM
TEMPERA
TURE) button, the
temperature will change by 1°C.
(T
emperature setting range from the auto set temperature is not higher or
lower than 3°C.)
Press the
(ST
OP) button.
•
A
short beep sounds and dry cool operation stops.
Humidity
to be set
T
emperature
to be set
Based on the detected outside and room temperature,
the temperature is set on an hourly basis within the range
of 24~28°C.
•
Even if the room temperature
reached the preset temperature,
the air conditioner may continue
to operate if the preset humidity
has not been reached.
50% when temperature above 27°C is set.
55% when temperature of 26°C is set.
60% when temperature below 25°C is set.
Dry
intermittent
operation
Dry cool operation
Operation
stops
Cooling
operation
About 3ºC
Approx. 3°C if outside temp. is
below approx. 32°C.
Approx. 1°C if outside temp. is
above approx. 32°C.
Room temperature set
Current room temperature
About 1ºC
The operation mode may automatically be switched to cooling or heating for temperature control.
If the room temperature is lower than the preset temperature, intermittent operation (repeat of operation state
and stop state) is performed to avoid excessive lowering of temperature and to control the humidity
.
DEUTSCH
FRANÇAIS
ITALIANO
SPANISH
PORTUGUÊS
∂ÏÏËÓÈο
РУССКИЙ
– 16 –
18SH3_OM.indd 1618SH3_OM.indd 16
2012-2-21 14:45:282012-2-21 14:45:28
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...