BASIC MODE
MODEL RAS-10SH , 14SH , 18SH
– 6 6 –
AUTO
HI
MED
Sleep operation
(SLEEP button on)
Basic mode of
the temperature
controller
LOW
SILENT
Operation
mode
Cooling
Heating
OFF timer
ON timer
OFF
→
ON
timer
Basic mode of
the START/STOP
switch
Stainless plasma air purifying
Special automatic (normally not used)
Automatic
Operation mode
Automatic
Mode change during operation
Special automatic
Starting in the state specified below enters the product
into special automatic operation mode.
<
Startup condition
>
With a telecommunication signal entered, turn on the
power. (The product will automatically be activated.)
<
End condition
>
Activating a remote control operation sets the product
into usual operation mode.
Special automatic mode is based on automatic mode
with the following differences:
While the compressor is not stopped, a "HI"
operation is conducted.
While the compressor is not stopped, a "MED"
operation is conducted.
While the compressor is not stopped, a "LOW"
operation is conducted.
While the compressor is not stopped, a "SILENT" operation
is conducted.
For details, see the basic mode for dehumidification and
Dry cool.
1. While the compressor is stopped, the indoor unit is
stopped too.
2. For the room temperature categories, see the item for
dehumidification operation.
The wind changes between "LOW" and "MED" depending
on the room temperature.
Room temperature category
Fan speed
Category 1
Category 2
Category 3
Category 4
LOW
LOW
MED
MED
Start
Stop
Start
Stop
START/STOP button
Operation monitor lamp
CANCEL button
Timer memory
(Reserved time changed)
(OFF timer while stopped)
START/STOP button
Timer lamp
Remote controller "RESERVED" lit
RESERVE button
Operation monitor lamp
CANCEL button
Timer memory
(Reserved time changed)
(OFF timer while stopped)
START/STOP button
Timer lamp
Remote controller "RESERVED" lit
RESERVE button
Operation monitor lamp
OFF
ON
ON
OFF
ON
OFF
PM
:
1
.
00 PM3
:00 PM5 :
00
PM
:
1
.
00 PM3
:00 PM5:
00
PM
:
1
.
00 PM3
:00 PM5:
00
START/STOP switch
CANCEL button
Timer memory
(
OFF
→
ON timer
)
(
ON
→
OFF timer
)
(
ON
→
OFF timer while operated
)
(OFF
→
ON timer while stopped)
PM
:
1
.
00 PM3
:00 PM5:
00
ON
OFF
Timer lamp
Remote controller "RESERVED" lit
RESERVE button
Operation monitor lamp
Activates a "HI" operation regardless of
the room temperature.
Activates a "MED" operation regardless of
the room temperature.
Activates a "LOW" operation regardless of
the room temperature.
Activates a "SILENT" operation regardless of
the room temperature.
HI
HI
MED
MED
LOW
LOW
Activates only a wind operation at the fan speed
set regardless of the room temperature.
"Super-LOW", "LOW", "MED", "HI",
"Super-HI" and "Stop" are produced depending on the
room temperature and time. If the room temperature goes below
18
℃
during a "Super-LOW" operation other than preheating,
the product enters "Stop" mode. (This is reset at 18.33
℃
.)
Note also that the product produces "Super-HI" while the
compressor is running at its maximum speed after hot dash and
defrost reset.
"Super-LOW", "LOW", "MED" and "Stop" are
produced depending on the room temperature and time. If the
room temperature goes below 18
℃
during a "Super-LOW"
operation other than preheating, the product enters "Stop" mode.
(This is reset at 18.33
℃
.)
50℃
44℃
"Super-LOW", "LOW" and "Stop" are produced depending on the room
temperature and time. If the room temperature goes below 18
℃
during a
"Super-LOW" operation other than preheating, the product enters "Stop" mode.
(This is reset at 18.33
℃
.)
Note also that the product controls the fan speed by adjusting the heat exchanger
temperature, thereby controlling the overload as shown in the figure below.
Provided that, in "SILENT" mode and when overloaded, "LOW" is produced.
When overloaded
LOW, SILENT
For details, see the basic operation for heating.
MED
LOW
SILENT
Other than what is specified
on the left
Heat exchanger
temperature
31.
66
30.
66
℃
"Super-LOW", "SILENT", "LOW", "MED", "HI",
"Super-HI" and "Stop" are produced depending on the room
temperature, time and heat exchanger temperature. If the room
temperature goes below 18
℃
during a "Super-LOW" operation
other than preheating, the product enters "Stop" mode.
(This is reset at 18.33
℃
.)
While the compressor is running
at very slow speed during hot dash
19
18
23
25
41.
66
35.
66
Timer operation
Fan speed mode (indoor unit)
A "Super-HI" is produced during cool dash and
while the compressor is running at its maximum speed.
A "HI" is produced in all other cases. A "LOW"
is produced while the compressor is stopped.
For details, see the basic mode for cooling.
0
.6
6
℃
1
.3
3
℃
1
.3
3
℃
3′
The wind changes from "HI" to "MED" or
"LOW" depending on the room temperature.
(The compressor is forcefully stopped for 3 minutes.)
ON
OFF
ON
Same as left
Same as left
Same as left
A "LOW" is produced while the compressor is stopped.
Operation mode
14
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
1
5
16 17 18 19 20 21 22 23 24 2
5
26 27 28 29 30
External air temperature at the start of operation (
℃)
Temperature setting for cooling:27
℃
Fan speed mode: "AUTO", "LOW", "SILENT"
Temperature setting for heating:23
℃
Fan speed mode: "AUTO", "LOW", "SILENT"
Temperature setting for dehumidification: Room temperature
at the start of operation
Fan speed mode: "AUTO", "LOW", "SILENT"
Heating
Dehumidification
Cooling
Dehumidification,
Dry cool
Dehumidification and Dry cool only by using the operation
selector button. This doesn't include the dehumidification and
Dry cool by using the quick dehumidification or the Dry cool button.
START/STOP switch
Fan
speed
Operation monitor lamp
·
Activates a sleep operation after the setting
is made.
·
Activates "sleep operation in progress".
·
SILENT
(sleep) operation.
Room temperature
Cooling temperature
setting
HI
MED
LOW
Compressor
Thermometer judgment
1. A "HI" is produced after the onset of operation until the thermometer is
turned off for the first time. (A "Super-HI" is produced while the cool-dash
compressor is operated at the maximum speed.)
2. The product is stopped while the thermometer is off.
3. A "Super-LOW" is produced if the thermometer does not become turned on
3 minutes after the thermometer is turned off.
·
Same as left
·
For details, see Cooling "Sleep".
·
Same as left
·
For details, see Dehumidification and Dry cool "Sleep".
·
Same as left
·
For details, see Heating "Sleep".
·
Same as left
·
This activates the "sleep operation" in each operation
mode.
HI or super-HI (Setting:
room temperature)
Heat exchanger temperature
·
·
Judgment is made based on the room temperature and external
air temperature.
"Cooling": external air temperature
≧
25
℃
, or 21
℃
≦
external air
temperature
<
25
℃
, and room temperature > 27
℃
"Heating": external air temperature
<
18
℃
, or 18
℃
≦
external air
temperature
<
21
℃
, and room temperature
≦
23
℃
"Dehumidification": 21
℃ ≦
external air temperature
<
25
℃
, and
room temperature
≦
27
℃
, or 18
℃ ≦
external air temperature
<
21
℃
, and room temperature
Rejudgment is made after one hour.
>
23
℃
Room temperature at the start of operation (
℃
)
Heating
Cooling
Dehumidification
Note (1) The temperature setting can be varied by
±
3
℃
by
using the room temperature control buttons and
.
Operation mode is rejudged every hour
similarly to what is done at the start of
operation.
(Provided that dehumidification is not
conducted.)
At the start of operation, operation mode is
set by controlling the room temperature.
←
3
3
3
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...