– 67 –
Outdoor unit
Rating
Room two-way valve
Open
Stop
Operation
Operation
Cooling temperature setting
Basic mode for cooling
1
℃
△T
CM
A
X
0.
6
6
℃
1
.3
3
℃
1
.3
3
℃
0.
3
3
℃
60″
60″
15″
60″
15″
15″
1″
1″
10″
10″
20min.
(CMAX)
(CSTD)
(CSTD2)
0
Lo
CLMXTP
Lo
Lo
CMI
NH
I
CMI
NSZ
STARCPL
CMI
N
+
SH
I
FTC
Room temperature
remote control
temperature setting
Cool dash period
Fan speed
set to AUTO
START/STOP switch
Stop
Thermometer judgment
Thermometer
OFF
Indoor unit
Super-HI
HI
MED
LOW
SILENT
Super-LOW
(If the fan speed is not set to AUTO, the fan speed will reach the setting.)
Operation lamp
Compressor speed
Maximum
Minimum
Latch-type reversing valve
Notes:(1) The condition fro entering cool dash mode is when the wind velocity is set to AUTO or "HI" and the product is started, or when, during cooling operation,
the fan speed mode is changed to either AUTO or "HI", and when the compressor speed (P term) due to the temperature difference between the temperature
setting (including the correction shift alone) and room temperature is CMAX or higher.
(2) The condition for the cool dash compressor terminating its maximum running speed is
①
25 minutes after the startup of cool dash,
②
when the room temperature reaches
the cooling temperature setting (including the cooling shift) -1
℃
and 20 minutes passed after the maximum running speed, and
③
the thermometer is turned off.
(If the cool dash is terminated in
①
, the constant-speed period is not executed. Fuzzy control is initiated instead.)
(3) The thermometer-off temperature during cool dash is the cooling temperature setting (including the cooling shift) -3
℃
. After the thermometer is turned off, the cool dash is
terminated and fuzzy control is initiated.
(4) The minimum ON time of the compressor is 3 minutes, while the minimum OFF time is 3 minutes.
(5) The time limit when the compressor's maximum speed (CMAX) can be maintained during a normal cooling operation (other than cool dash) is within 60 minutes if the room
temperature is 30
℃
or less. If the room temperature is more than 30
℃
, there is no limit.
(6) The fan speed of the remote control is set to "MED", the compressor maximum speed is CJKMAX.
(7) If the fan speed of the remote control is set to "LOW", the compressor's maximum speed is CBEMAX.
(8) If the fan speed of the remote control is set to "SILENT" or "sleep", the compressor's maximum speed is CSZMAX.
(9) The compressor's maximum speed in powerful operation is CMAX2.
(10) If the room temperature is 25
℃
or more and the humidity 57% or more, the compressor's minimum speed is accelerated at increments of 100 min
-1
. The upper limit is 1,400 min
-1
.
If the product deviates from the high-temperature, high-humidity conditions, the compressor's minimum speed is decelerated at increments of 50 min
-1
. The lower limit is
CMINHI. (The cooling humidity is limited.)
(11) While the cooling thermometer is off, the indoor unit produces slight wind.
(12) Some 30 minutes later at a humidity of 65% or less, the cooling rated speed is CSTD2.
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...