Control by heat exchanger temperature
Thermometer off
Thermometer
off
Operation
Stop
3′
60″
0.
6
6
℃
0.
6
6
15″
15″
15″
15″
15″
10″
1
.3
3
℃
20
Defrost signal
(WMAX)
(WSTD)
0
Lo
Lo
Lo
Lo
Lo
(WMAX2)
WMAX2
H
i
STARCPL
WMIN
WMINHI
WMINSZ
1″
1″
1″
Basic mode for heating
Heating temperature setting
remote control setting
+ SHIFTW
or
+ SFTSZW
Dash per
Dash period
iod
Dash period
fan speed
set to AUTO
Operation
Operation
Stop
Stop
Preheating canceled
Maximum length 3'
Control by heat exchanger temperature
Notes: (1) The condition for entering hot dash is when the fan speed mode is set to AUTO or "HI" and the product is started, or when heating is in progress and
the fan speed mode is changed to AUTO or "HI" and the compressor's speed (P term) due to the temperature difference between the temperature setting
(including the correction shift only) and room temperature is WMAX or more, and when the room temperature is 18
℃
or less and the external temperature is 10
℃
or less.
(2) The condition for terminating the hot dash compressor's maximum speed period is:
①
when the room temperature reaches the heating temperature setting (including
the heating shift) + 0.66
℃
and
②
when the thermometer is off.
(3) The thermometer-off temperature during hot dash is the heating temperature setting (including the heating shift) +3
℃
. After the thermometer is turned off,
the hot dash is terminated and fuzzy control is initiated.
(4) The minimum on-time for the compressor is 3 minutes, while the minimum off-time is 3 minutes.
(5) The time limit where the compressor's maximum speed (WMAX) or (WMAX2) can be maintained during a normal heating operation (other than hot dash) is within 120
minutes at a room temperature of 18
℃
or more. There is no limit if the room temperature is 18
℃
or less or the external temperature is 2
℃
or less.
(6) During preheating, during defrost (including the balancing time after the end of defrost), and during auto-fresh defrost, the operation lamp will blink with cycles of "lit 2
seconds and off 1 second."
(7) Preheating judgment is as follows: when the product is started with the START/STOP switch, the heat exchanger temperature
<
24
℃
and preheating is turned on.
When the heat exchanger temperature is
>
24
℃
, preheating is canceled.
(8) When the fan speed mode is set to "MED", the compressor speed is WJKMAX or less. During "LOW" operation, it is WBEMAX or less. During "quiet" operation,
it is limited to WSZMAX or less.
(9) When in super-LOW mode the room temperature is 18
℃
or less, the indoor unit is stopped and the product starts again at super-LOW at 18
℃
+0.33
℃
.
Provided that, during preheating, and after defrost, the super-LOW operation during preheating is stopped at a heat exchanger temperature of 16
℃
or less.
(10) During hot dash (only when the room temperature - external temperature
<
RTOSTA), during powerful operation, and when the external temperature -5
℃
or less,
WMAX2 is used as the compressor's maximum speed.
Control by heat
exchanger temperature
Control by heat
exchanger temperature
Control by heat
exchanger temperature
Preheating period
set to WMAX
Preheating period
set to WMAX
Outdoor unit
Rating
Room two-way valve
START/STOP switch
Thermometer judgment
Indoor unit
Super-HI
HI
MED
LOW
SILENT
Super-LOW
Operation lamp
Compressor speed
Maximum
Minimum
Latch-type reversing valve
Preheat judgment
Open
Thermometer
off
Preheating canceled
– 69 –
Summary of Contents for RAC-10SH3
Page 57: ... 55 MODEL RAC 18SH3 Unit mm 580 5 600 345 299 19 5 ...
Page 60: ... 8 5 WIRING DIAGRAM MODEL RAS 10SH3 3 H S 4 1 S A R 3 H S 8 1 S A R INDOOR UNIT ...
Page 62: ... 0 6 MODEL RAC 18SH3 OUTDOOR UNIT WHT YEL RED INDOOR UNIT ...
Page 64: ... 2 6 3 H S 8 1 S A R 3 H S 4 1 S A R 3 H S 0 1 S A R L E D O M ...
Page 150: ... 8 4 1 MODEL RAC 18SH3 ...
Page 153: ...HHAW NO 0060E RAS 10SH3 RAC 10SH3 RAS 14SH3 RAC 10SH3 RAS 18SH3 RAC 18SH3 ...